Installation Instructions
NetWay1/NetWay1X - 1 -
Overview:
Altronix NetWay1/NetWay1X are single port PoE/PoE+ injectors which provide power and passes data (e.g. video) for
PoE/PoE+ compliant devices. Devices may be located up to 100m from NetWay1/NetWay1X. To extend data distance for
an additional 100m use NetWayXT/NetWayXTX repeater modules.
General Specifications:
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and
authorities having jurisdiction. Wiring should be UL Listed and/or Recognized wire suitable for the application.
Unit is intended to be used with a UL Listed Class 2 or LPS (limited power supply). NetWay1/NetWay1X is not intended
to be connected to outside plant leads and should be installed indoors within the protected premises.
NetWay1/NetWay1X is intended for indoor use only.
1. Mount NetWay1/NetWay1X in desired location utilizing the mounting hole (Figs. 1a and 2a, pg. 2). Use a proper
fastener and/or wall anchor when securing NetWay1/NetWay1X with screw through its mounting hole to the wall.
2. Connect 24VAC/24VDC to terminals marked [24VAC/VDC Input], (Figs. 1b and 2b, pg. 2). Use 22AWG-16AWG
wire for this connection. Input power should be a UL Listed Access Control power-limited power supply (for
UL294 applications) or Class 2 rated transformer/power supply (for UL60950-1 applications).
3. Connect structured cable from port marked [IN] on NetWay1/NetWay1X to the corresponding input of an
UL Listed ethernet switch or video server (Figs. 1b, 2b, pg. 2).
4. Connect structured cable from port marked [OUT] on the NetWay1/NetWay1X to PoE device (Figs. 1b, 2b, pg. 2).
All interconnected devices must be UL Listed.
5. Port status LED will illuminate indicating normal operation (Figs. 1c, 2b, pg. 2).
6. To initiate PoE shutdown connect 12VAC to 24VAC or 5VDC to 24VDC to the input terminals marked [PoE Shutdown]
on the NetWay1/NetWay1X (Figs. 1b, 2b, pg. 2). The PoE output voltage may be shutdown by manually applying
voltage in the rated range (PoE Shutdown Voltage Range in Specifications). Upon applying voltage the output will
drop to zero volts.
Removal of voltage from the shutdown terminals or applying zero volts to the shutdown terminals will allow the PoE
output to operate normally to supply power to PoE compliant devices.
Note: Return to normal operation from shutdown can take about 4 seconds. Although there is no output voltage to
power PoE devices during shutdown, data signals may still be present on the data pair lines of the CAT5 cable.
Agency Listings:
• NetWay1:
- UL/CUL Listed for Information Technology
Equipment (UL 60950-1). UL Listed for Access
Control Systems (UL294), Power over Ethernet
(PoE) for Access Control (UL294B).
- CUL Listed - CSA Standard C22.2 No.205-M1983,
Signal Equipment.
- CE approved.
• NetWay1X:
- UL/CUL Listed for Information Technology
Equipment (UL 60950-1).
- CUL Listed - CSA Standard C22.2 No.205-M1983,
Signal Equipment.
- CE approved.
Input:
• NetWay1: 24VAC @ 1.2 amp or 24VDC @ 1.2 amp.
• NetWay1X: 24VAC @ 1.5 amp or 24VDC @ 1.5 amp.
PoE/PoE+:
• NetWay1: IEEE 802.3af (15W) compliant.
• NetWay1X: IEEE 802.3at (30W) and
IEEE 802.3af (15W) compliant.
Features:
• PortstatusLED.
• PoEmanualshutdown(For UL 60950-1 applications
only) (see Technical Specifications table pg. 4).
• Autodetectionandprotectionoflegacy
non-PoE cameras/devices.
• Datarate:10/100BASE-Tcompliant.
• Compactinsulatedhousing.
Dimensions (W x L x H approx.):
NetWay1:
2.5” x 3.8” x 1” (63.5mm x 96.52mm x 25.4mm).
NetWay1X:
3.5” x 3.5” x 1” (88.89mm x 88.89mm x 25.4mm).
NetWay1 - Single Port PoE Injector for Standard NetWork Infrastructure
NetWay1X - Single Port PoE/PoE+ Injector for Standard NetWork Infrastructure
®
Rev. 032814
Installation Guide