Data Sheet
MOM5 power distribution module converts one (1) non power-limited DC
voltage input to five (5) power-limited outputs. Each output will route power
to a variety of access control hardware and devices which includes Mag Locks,
Electric Strikes, Magnetic Door Holders, etc. These outputs will operate in both
fail-safe and fail-secure modes. Controlled trigger input is achieved through
normally open (NO) or normally closed (NC) supervised input or the polarity
reversal from an FACP (Fire Alarm Control Panel). A form “C” dry output relay
will enable HVAC Shutdown, Elevator Recall or trigger auxiliary devices.
Input:
• 12VDC or 24VDC from power supply.
Output:
• 12VDC@2.5ampor24VDC@2.5ampoutput.
• Five(5)individualClass2RatedPTCprotected
power-limited outputs.
• Currentlimitis12VDCor24VDC@2amp
per output.
Fire Alarm Interface:
• FireAlarmPanelorAccessControlSystemtrigger
inputs, (N.O. or N.C. supervised trigger input and
polarity reversal trigger input).
Visual Indicators:
• RedLED’sindicateconditionofeachpoweroutput.
• Power&inputtriggerLED’s.
Supervision:
• Powerfailsupervisionrelay
(Form“C”contactrated1amp@28VDC/115VAC).
• Outputrelayindicatesthatunitistriggered.
(Form“C”contactrated1amp@28VDC/115VAC).
• InterfaceswithmostDCPowerSupplies.
Mechanical:
• Boarddimensions(LxWxHapprox.):
5.25”x3.5”x1”(133.35mmx88.9mmx25.4mm).
• Productweight:0.3lbs.(0.13kg).
• Shippingweight:0.4lbs.(0.18kg).
MOM5 Multi-Output
Access Control Power Distribution Module
Rev.DSMOM5_11272013
Overview
Specifications
Mounting Diagram
Altronix Corp. - 140 58th Street, Brooklyn, NY 11220 • 718-567-8181 • 888-258-7669 • altronix.com
Agency Approvals
UL Listed Sub-Assembly for Access Control
SystemUnits(UL294)andforPowerSupplies
forFireProtectiveSignalingSystems(UL1481).
• NFPA72compliant.
0.14"
3.56mm
2.4"
60.96mm
4.9"
124.46mm
5.25"
133.35mm
3.5"
88.9mm
Ø0.156"
3.96mm
0.19"
4.83mm
MOM5