Data Sheet

Maximal11FD
Access Power Controller
Rev. DSMaximal11FD_05192015
Maximal11FD Access Power Controller distributes and switches power to access
control systems and accessories. It converts a 120VAC 60Hz input into sixteen
(16) independently controlled 12VDC or 24VDC PTC protected power-limited
outputs. The outputs are activated by an open collector sink or normally open (NO)
dry trigger input from an Access Control System, Keypad, Push Button, REX
PIR, etc. Unit will route power to a variety of access control hardware devices
including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will
operate in both Fail-Safe and/or Fail-Secure modes. The FACP Interface enables
Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary
devices. The fire alarm disconnect feature is individually selectable for any or all
of the sixteen (16) outputs. All interconnecting equipment must be UL Listed.
Overview
Specifications
Input:
120VAC 60Hz, 7.0 amp input.
Power supply input options:
a) Two (2) common power input for either ACM8CB
and lock power (factory installed).
b) Two (2) isolated power inputs (external power
supply is required). Current is determined by the
power supply connected, not to exceed a
maximum of 10 amp total.
Sixteen (16) Access Control System trigger inputs.
Input options:
a) Sixteen (16) normally open (NO) inputs.
b) Sixteen (16) open collector inputs.
c) Any combination of the above.
Output:
12VDC and/or 24VDC outputs.
Maximum output current:
Options P/S 1 P/S 2
A 12VDC @ 3.3 amp 12VDC @ 3.3 amp
B 12VDC @ 3.3 amp 24VDC @ 3.6 amp
C 24VDC @ 3.6 amp 24VDC @ 3.6 amp
Power-limited outputs.
Sixteen (16) independently controlled outputs can be
Fail-Safe and/or Fail-Secure power outputs.
Sixteen (16) auxiliary power outputs (unswitched)
(outputs are rated 2.5 amp).
Filtered and electronically regulated outputs (built-in
power supply).
Thermal and short circuit protection with auto reset.
Fuse Ratings:
Power Supply input fuse rated @ 5 amp/250V.
ACM8CB boards main fuse is rated at 10 amp.
PTC outputs are rated @ 2 amp each.
Supervision:
AC fail supervision (form “C” contacts).
- Notification trigger is selectable for
30 seconds (factory set) or 2 hours.
Battery fail and presence supervision (form “C” contacts).
Supervision (cont’d):
Low power shutdown. Shuts down DC output terminals
if battery voltage drops below 71-73% for 12V units
and 70-75% for 24V units (depending on the power
supply). Prevents deep battery discharge.
Features:
Fire Alarm disconnect (latching or non-latching) is
individually selectable for any or all of the
sixteen (16) outputs.
Fire Alarm disconnect input options:
a) Normally open (NO) or normally closed (NC) dry
contact input.
b) Polarity reversal input from FACP signaling circuit.
Alarm output relay indicates that FACP input is
triggered (form “C” contact rated @ 1 amp 28VDC).
Battery Backup:
Built-in charger for sealed lead acid or gel type batteries.
Maximum charge current 1.54 amp per p/s board.
Automatic switch over to stand-by battery when AC fails.
Zero voltage drop when unit switches over to battery
backup (AC failure condition).
Visual Indicators:
Red LEDs indicate outputs are triggered
(relays energized).
Green LED indicates FACP disconnect is triggered.
AC input and DC output LED indicators.
Electrical:
Operating temperature: 0º C to 49º C ambient.
• BTU/Hr.:
- 12VDC: 40.54 BTU/Hr.
- 24VDC: 88.44 BTU/Hr.
- 12VDC and 24VDC: 64.49 BTU/Hr.
System AC input VA requirement: 840VA.
Mechanical:
Enclosure Dimensions (H x W x D approx.):
26” x 19” x 6.25” (660.4mm x 482.6mm x 158.75mm).
Enclosure accommodates up to four (4) 12AH batteries.
Product weight (approx.): 33.4 lbs. (15.2 kg).
Shipping weight (approx.): 40.7 lbs. (18.2 kg).
Maximal11FD