Installation Instructions
LINQ8PD/LINQ8PDCB - 3 -
Terminal/Connector Identification:
Terminal/Legend Description
GND, RESET FACP reset.
GND, FACP EOL Connects to EOL or next LINQ8PD(CB).
+ RET -- FACP EOL, or next LINQ8PD(CB).
FACP -- IN + Wet input from FACP +.
FACP RLY 1, 2 FACP reporting relay.
Downlink Connection to power supply or second LINQ8PD(CB) module.
Uplink Connects to next LINQ8PD(CB) upstream from this module. If this is the first LINQ8PD(CB) in the daisy chain this connector is not used.
BAT Local LED Indicates battery(ies) thresholds.
FACP/AC/BAT LEDs Indicates status of FACP, AC and Battery.
Heartbeat LED Indicates the LINQ8PD(CB) is operational.
RJ45 Ethernet: LAN or laptop connection enables LINQ8PD(CB) programming and status monitoring.
USB Laptop connection enables LINQ8PD(CB) initial setup and programming.
Battery Fail
NC, C, NO
Indicates low battery condition, e.g. connect to alarm panel. Relay normally energized when DC power is present.
Contact rating 1 amp @ 30VDC.
AC Fail
NC, C, NO
Indicates loss of AC power, e.g. connect to audible device or alarm panel. Relay normally energized
when AC power is present. Contact rating 1 amp @ 30VDC (power-limited).
+ OUT1 -- to
+ OUT8 --
24VAC/28VAC or 12VDC/24VDC continuous output.
AC / NO, C Connection to
[
AC Fail
]
terminals on power supply.
BAT / NO, C Connection to
[
BAT Fail
]
terminals on power supply.
+ BAT OUT -- Connection to
stand-by batteries
.
+ BAT IN -- Connection to
[
+ BAT --
]
terminals on power supply.
-- INP2 + Second AC or DC power supply input. Note: Do not connect AC and DC simultaneously to INP1 and INP2.
-- INP1 + First AC or DC power supply input. Note: Do not connect AC and DC simultaneously to INP1 and INP2.
LED Diagnostics:
LED Flash Codes Description
BAT LOCAL
ON Charge/Discharge current working properly
Blinking Charge/Discharge current on the battery exceed limits
FACP
ON FACP triggered
OFF FACP released
AC
ON Input signal active
OFF Input signal inactive
BAT
ON Input signal active
OFF Input signal inactive
OUT1-OUT8
ON Output is ON and working properly
OFF Output is OFF
Blinking Output is ON and voltage and/or current exceeds limits
A B C D E F G
H
I J K L
M
N O
P
Q
R S T
U V
A B C D E F G
H
I J K L
M
N O P
Q
R S T
U V
A B C D E F G
H
I J K L
M
N O P
Q
R S T
U V
A B C D E F G
H
I J K L
M
N O P
Q
R S T
U V
A B C D E F G
H
I J K L
M
N O P
Q
R S
T
U V
A B C D E F G
H
I J K L
M
N O P
Q
R S T
U V
A B C D E F G
H
I J K L
M
N O P
Q
R S T
U V
A
B
C D E F G
H
I J K L
M
N O P
Q
R S T
U V
A B
C
D E F G
H
I J K L
M
N O P
Q
R S T
U V
A B C
D
E F G
H
I J K L
M
N O P
Q
R S T
U V
A B C D
E
F G
H
I J K L
M
N O P
Q
R S T
U V
A B C D E
F
G
H
I J K L
M
N O P
Q
R S T
U V
A B C D E F G
H
I J K L
M
N O P
Q
R S T
U V
A B C D E F G
H
I J K L
M
N O P
Q
R S T
U V
A B C D E F G
H
I
J K L
M
N O P
Q
R S T
U V
A B C D E F G
H
I
J
K L
M
N O P
Q
R S T
U V
A B C D E F G
H
I J
K
L
M
N O P
Q
R S T
U V
A B C D E F G
H
I J K
L
M
N O P
Q
R S T
U V
A B C D E F G
H
I J K L
M
N O P
Q
R S T
U V
A B C D E F G
H
I J K L
M
N
O P
Q
R S T
U V
A B C D E F G
H
I J K L
M
N
O
P
Q
R S T
U V