Instructions
HubWay Passiive Unit - 3 -
Installation Instructions:
1. Attach mounting brackets to HubWay unit for rack or wall mount installation (Figs. 6-7, pg. 8). Affix rubber pads
to HubWay for shelf installation (Fig. 8, pg. 8).
2. Secure the unit in a rack, mount unit to a w
all or place unit on a shelf as desired (unit should be spaced at least
3” from any video monitors).
3. Set illuminated master power disconnect circuit breaker to the (OFF) position (Fig. 5, pg. 7).
4.
Plug the g
rounded AC line cord (included) into the IEC 320 connector of the HubWay8CD/HubWay16CD
unit (Fig. 1g, pg. 4). Insert the plug end of the line cord into a grounded AC receptacle.
5.
Set v
oltage output selector switch of each camera channel for 24VAC or 28VAC (Fig. 1d, pg. 4).
6. Connect the BNC video outputs for HubW
ay8CD/16CD Channels 1 - 8 (Channels 1-16) to the
corresponding video inputs on the head end equipment (DVR) (Fig. 1f, pg. 4).
7.
Connect the RS422/RS485 output of the head end equipment (D
VR) to the one (1) or both data input terminal
blocks of the HubWay8CD or HubWay16CD unit (polarity must be observed) (Fig. 1e, pg. 4).
Note: The Data input terminals of the HubWay8CD or HubWay16CD must be wired in parallel for proper operation.
When using f
ix
ed cameras disregard this step.
8. Connect Video Balun/Combiner at camera 1 to the HubWay8CD or HubWay16CD unit utilizing CAT-5 or higher
structured cable. Plug the RJ45 connector at one end of the structured cable into the RJ45 jack marked [Channel 1]
of the HubWay8CD/16CD (Fig. 1a, pg. 4). Plug the RJ45 connector at the opposite end of the structured
cab
le into the RJ45 jack of the
Video Balun/Combiner located at camera 1.
• For 24VAC cameras use Altronix model HubWayAv Video Balun/Combiner (Figs. 2a, 2b, pg. 5).
•
F
or 12VDC cameras use Altronix model HubWayDv Video Balun/Combiner (Figs. 2c, 2d, pg. 5).
• For non-isolated 12VDC cameras use Altronix model HubW
ayDvi Video Balun/Combiner (Figs. 2c, 2d, pg. 5).
Repeat steps 6-9 for each additional camera (Channels 2-8 or Channels 2-16).
Note: When a particular camera e
xceeds the maximum distance for po
wer transmission, a local
external power source is required. Optionally, an Altronix HubSat4D Passive UTP Transceiver Hub with Integral
Camera Power may be utilized (Fig
. 4a, pg. 6). The combined total cable distance must not e
xceed 750 ft. for
video transmission between the HubWay8/16 and each camera routed through the HubSat4D.
9. Set illuminated master power disconnect circuit breaker to the RESET (ON) position (Fig. 5, pg. 7) and measure the
output voltage at the pow
er output of each
Video Balun/Combiner (Figs. 2b, 2d, pg. 5) before powering each camera
to insure proper operation and av
oid possible damage.
• HubWayAv - Terminals marked [AC POWER] (Figs. 2a, 2b, pg. 5).
• HubWayDv/HubWayDvi -
T
erminals marked [– 12VDC +] (Figs. 2c, 2d, pg. 5).
10. Set illuminated master po
wer disconnect circuit breaker to the (OFF) position to make the final connections
(Fig. 5, pg. 7).
11. Connect the power outputs of the HubWayAv, HubWa
yDv or HubW
ayDvi Video Balun/Combiners to the
power inputs of the cameras (Figs. 2a-2d, pg. 5). Polarity must be observed.
12. Connect the terminals marked [+ D
A
TA --] of the HubWayAv or HubWayDv Video Balun/Combiners to the data
terminals of the cameras for PTZ control (Figs. 2a-2d, pg. 5). Polarity must be observed.
When using fixed cameras disregard this step.
13. Connect the BNC connectors of the HubWa
yA
v, HubWayDv or HubWayDvi Video Balun/Combiners to the
BNC video outputs of the cameras (Figs. 2a-2d, pg. 5).
14.
Upon completion of wiring set illuminated master po
wer disconnect circuit breaker to the RESET (ON) position
(Fig. 5, pg. 7).
15. The power LEDs (Red) located on the front of the HubWay8CD/16CD will illuminate when AC power
is present (Fig. 1c, pg. 4).
Note: If any of these LEDs are not illuminated either a voltage output selector switch is in the OFF position or the
PTC is tripped for that channel.
T
o reset the PTC:
1.
Set the voltage output selector switch for that corresponding channel to the OFF position. Switch must remain
in the OFF position for approximately 2 minutes in order for the PTC to reset.
2. Eliminate the trouble condition (short circuit or overload).
3. Set the voltage output selector switch for 24VAC or 28VAC (Fig. 1d, pg. 4).
16. A
C LEDs (Green) of the HubW
ayAv or DC LEDs (Red) of the HubWayDv/HubWayDvi Video Balun/Combiners
will illuminate indicating power is present at the cameras (Fig
. 2b, 2d, pg. 5).