Installation Instructions User guide
- 4 - HubSat4Di
3. SetilluminatedmasterpowerdisconnectcircuitbreakertotheRESET(ON)position(Fig.4a,pg.6)power
LEDs(Green)oftheHubSat4DiwillilluminatewhenACpowerispresent(Fig.1e,pg.4)and HubWayAv,
HubWayDv or HubWayDvi Video Balun/Combiner LEDs will illuminate indicating power is present
(Fig.2b,2d,pg.6).
4. Measure the output voltage at each Video Balun/Combiner (Figs.2b,2d,pg.6) before making connections to
each camera to insure proper operation and avoid possible damage.
5. Setilluminatedmasterpowerdisconnectcircuitbreakertothe(OFF)position(Fig.4a,pg.6).
6. Connect power outputs of HubWayAv, HubWayDv or HubWayDvi Video Balun/Combiners to power inputs
of cameras (Figs.2a-2d,pg.6).Polarity must be observed.
• HubWayAv-Terminalsmarked[ACPOWER](Figs.2a,2b,pg.6).
• HubWayDv/HubWayDvi-Terminalsmarked[–12VDC+](Figs.2c,2d,pg.6).
7. Connect the terminals marked [+ DATA -- ] of HubWayAv, HubWayDv or HubWayDvi Video Balun/Combiners
to data input terminals of cameras for PTZ control (Figs.2b-2d,pg.6). Polarity must be observed.
When using fixed cameras disregard this step.
8. Connect the BNC connector of HubWayAv, HubWayDv or HubWayDvi Video Balun/Combiners to the
BNC video outputs of cameras (Figs.2b-2d,pg.6).
Fig.1-HubSat4DiCircuitBoard
1i-Channels 1-4:
CAT-5 or higher
structured cable
to cameras.
PVD1
VIDEO1 VIDEO2 VIDEO3 VIDEO4
PVD2 PVD3 PVD4
+ DATA -
DATA 1-4 VIDEO 1-4
28VAC
24VAC
28VAC
24VAC
28VAC
24VAC
28VAC
24VAC
OFF
OFF
OFF
OFF
AUX1 AUX2 AUX3 AUX4
1e-LED(s) 1-4:
Power output
indicators.
1a-BNC
Connector: Video
in from remote
camera video
out to DVR.
1g-Channels 1-4: Single CAT-5 or higher
structured cable out to HubWay8/16,
HubWayLD8/16,
HubWayLDH8/16 enables transmission
ofuptofour(4)videosignals.
1h-Data: CAT-5 or higher structured
cable to data port on HubWay8/16, HubWayLD8/16,
HubWayLDH8/16orheadendequipment(DVR).
1c-Power Terminals: 24VAC/28VAC power outputs.
1b-Output
PTCs: Protects
each output.
1f-Data:
RS422/RS485
input from head
endequipment
(DVR)forPTZ
control.
1d-Output
Voltage
Switches: Selects
24VAC/28VAC/
OFFforeachout-
put.