Installation Instructions User Manual

- 2 - eBridge1PCRX/PCTX
Installation Instructions:
WiringmethodsshallbeinaccordancewiththeNationalElectricalCode/NFPA70/ANSI,andwithalllocalcodesand
authoritieshavingjurisdiction.WiringshouldbeULListedand/orRecognizedwiresuitablefortheapplication.
eBridge1PCTX and eBridge1PCRX are not intended to be connected to outside plant leads and should be installed
indoors within the protected premises. eBridge1PCTX and eBridge1PCRX are intended for indoor use only.
1. eBridge1PCRX installation:
a. Secure unit to desired mounting surface with a proper fastening device utilizing the unit’s mounting hole
(Fig. 2a, pg. 3).Unitshouldbemountedinproximitytoethernetswitch/network,NVRorvideoserver.
b.Connect24VDCto56VDCClass2powersupplytowireinsertconnector[Power--- Input +] (polarity observed)
(Fig. 1, pg. 2).Use22AWG-16AWGwireforthisconnection.
c. Connectstructuredcablefromethernetswitch/NVR(networkvideoserver)toRJ45jackmarked[10/100BaseT]
(Fig. 2, pg. 3).
d.ConnectCoaxcabletoBNCconnectormarked[Coax](Fig. 2, pg. 3).
2. eBridge1PCTX installation:
a. Secure unit to desired mounting surface with a proper fastening device utilizing the case’s mounting hole
(Fig. 2a, pg. 3).Unitshouldbemountedinproximityofcamera/device.
b.ConnectstructuredcablefromIPcamera/devicetoRJ45jackmarked[10/100BaseT](Fig. 2, pg. 3).
c. ConnectCoaxcabletoBNCconnectormarked[Coax](Fig. 2, pg. 3).
Note:TheeBridge1PCRTXisdesignedtoaccommodateMegapixel,HD720,HD1080andVGA(SD)cameras.Itis
important to note that some high resolution and high frame rate cameras may demand faster headend processing ability,
such as a PC graphics card to present a quality image. If the headend processing equipment is insufficient in speed, the
image may show pixilation and latency. It is advisable to pretest system if unsure. Alternatively, frame rate and resolu-
tion may be reduced to accommodate system equipment.
Technical Specifications:
Parameter Description
Connections BNCforCoaxlink.RJ45forethernetlink.
Input power
requirements
24VDC/1,500mA,56VDC/900mA
Indicators
Blue:CoaxLink.
Yellow(RJ45connector):On-Link,Off-NoLink,Blinking-Activity.
Green(RJ45connector):On-100Base-TX,Off-10Base-T.
Green: Power.
Environmental
Conditions
OperatingAmbientTemperature:UL60950-1
eBridge1PCRX:
15W: --4ºFto113ºF(--20ºCto+45ºC).
30W for 24VDC: -- 4ºFto98.6ºF(--20ºCto+37ºC).
30W for 48VDC: -- 4ºFto113ºF(-- 20ºCto+45ºC).
eBridge1PCTX: -- 4ºFto120.2ºF(--20ºCto+49ºC).
Relative humidity: 85%, +/ --- 5%
Storage Temperature: --4ºto158ºF(---20ºto70ºC)Storage
Operating Altitude: --1000to6,561.679ft.(--304.8to2000m).
Regulatory
Compliance
UL/CULListedforInformationTechnologyEquipment(UL60950-1).
CE approved. C-Tick compliant.
Weights (approx.) Product: 5.1 oz. (0.144kg.),Shipping:7.76oz.(0.22 kg.)
Fig. 1 eBridge1PCRX eBridge1PCTX
Green LED
indicates
Power
Structured
Cable from
Ethernet Switch/NVR
Structured
Cable from
IP Camera/Device
Blue LED indicates
Coax Connection
Blue LED
indicates
Coax Connection
Green LED
indicates
Power
Yellow LED
indicates
PoE
Coax
Cable from
eBridge1PCT
24VDC-56VDC
--- Input +
Coax
Cable from
eBridge1PCR