Installation Instructions User Manual

- 2 - eBridge1PCR/PCT
Installation Instructions:
WiringmethodsshallbeinaccordancewiththeNationalElectricalCode/NFPA70/ANSI,andwithalllocalcodesand
authoritieshavingjurisdiction.WiringshouldbeULListedand/orRecognizedwiresuitablefortheapplication.
eBridge1PCT and eBridge1PCR are not intended to be connected to outside plant leads and should be installed indoors
within the protected premises. eBridge1PCT and eBridge1PCR are intended for indoor use only.
1. eBridge1PCR installation:
a. Secure unit to desired mounting surface with a proper fastening device utilizing the unit’s mounting hole
(Fig. 2a, pg. 3).Unitshouldbemountedinproximitytoethernetswitch/network,NVRorvideoserver.
b.Connect24VACClass2plug-intransformeror24VDC(polaritynotobserved)Class2powersupplytowireinsert
connector [Power Input] (Fig. 1, pg. 2).Use22AWG-16AWGwireforthisconnection.
c. Connectstructuredcablefromethernetswitch/NVR(networkvideoserver)toRJ45jackmarked[10/100BaseT]
(Fig. 2, pg. 3).
d. Connect Coax cable to BNC connector marked [Coax] (Fig. 2, pg. 3).
2. eBridge1PCT installation:
a. Secure unit to desired mounting surface with a proper fastening device utilizing the case’s mounting hole
(Fig. 2a, pg. 3).Unitshouldbemountedinproximityofcamera/device.
b.ConnectstructuredcablefromIPcamera/devicetoRJ45jackmarked[10/100BaseT](Fig. 2, pg. 3).
c. Connect Coax cable to BNC connector marked [Coax] (Fig. 2, pg. 3).
Note:TheeBridge1PCRTisdesignedtoaccommodateMegapixel,HD720,HD1080andVGA(SD)cameras.Itis
important to note that some high resolution and high frame rate cameras may demand faster headend processing ability,
such as a PC graphics card to present a quality image. If the headend processing equipment is insufficient in speed, the
image may show pixilation and latency. It is advisable to pretest system if unsure. Alternatively, frame rate and resolu-
tion may be reduced to accommodate system equipment.
Technical Specifications:
Parameter Description
Connections BNCforCoaxlink.RJ45forethernetlink.
Input power requirements 24VDC/1,000mA,24VAC/900mA
Indicators Blue:CoaxLink.
Yellow(RJ45connector):On-Link,Off-NoLink,Blinking-Activity.
Green(RJ45connector):On-100Base-TX,Off-10Base-T.
Green: Power.
Environmental
Conditions
OperatingAmbientTemperature:
UL60950-1
eBridge1PCR: ---4ºFto113ºF(---20ºCto+45ºC).
eBridge1PCT: ---4ºFto140ºF(---20ºCto+60ºC).
Relativehumidity:85%,+/--- 5%
Storage Temperature: ---4ºto158ºF(---20ºto70ºC)Storage
OperatingAltitude:---1000to6,561.679ft.(---304.8to2000m).
Regulatory Compliance UL/CULListedforInformationTechnologyEquipment(UL60950-1).
CE approved. C-Tick compliant.
Weights(approx.) Product: 5.1 oz. (0.144kg.),Shipping:7.76oz.(0.22 kg.)
Fig. 1 eBridge1PCR eBridge1PCT
Green LED
indicates
Power
Structured
Cable from
Ethernet Switch/NVR
Structured
Cable from
IP Camera/Device
Blue LED
indicates
Coax Connection
Blue LED
indicates
Coax Connection
Green LED
indicates
Power
Yellow LED
indicates
PoE
Coax
Cable from
eBridge1PCT
24VAC/VDC
Input
Coax
Cable from
eBridge1PCR