Installation Instructions User Manual
ALTV244series - 5 -
ALTV244175
XFMR
White Lead
24VAC or 28VAC fused output 1
(Follow same procedure
using terminals 2P & N
through 4P & N
fused outputs 2 through 4)
F1 F2 F3 F4
INPUT
1P 1N 2P 2N 3P 3N 4P 4N
LED
MAIN
FUSE
P
1P, 2P, 3P, 4P = FUSED OUTPUTS
1N, 2N, 3N, 4N = COMMON OUTPUTS
S
Power
Switch
Black
Lead
115VAC input
50/60 Hz,
1.5 amps
N
F1 F2 F3 F4
INPUT
1P 1N 2P 2N 3P 3N 4P 4N
LED
MAIN
FUSE
N
P
1P, 2P, 3P, 4P = FUSED OUTPUTS
1N, 2N, 3N, 4N = COMMON OUTPUTS
XFMR
White Lead
24VAC or 28VAC circuit breakered 1
(Follow same procedure
using terminals 2P & N
through 4P & N
fused outputs 2 through 4)
S
Power
Switch
Black
Lead
N
115VAC input
50/60 Hz,
1.5 amps
ALTV244175CB
NP S
NP S
24VAC
Output
(Yellow) (Black)
(Black) (Yellow)
28VAC
Output
Voltage Selection
Configuration