Installation Instructions
AL802ULADAJ - 7 -
Battery 2
Battery connection (non power limited)
Battery
Supervision
and AC
Supervision
Circuit
(power limited)
Nonpower-limited
Wire Strap
(from
Enclosure
to Door)
Battery 1
Divider
Green Lead
SW1
-- DC +
SW2
+ OUT1 --
OUT1 OUT2 OUT3 OUT4
INP1 INP2
FAULT
NO "REMOTE" C
NC CNOC "FAULT" NC
RESET
OUT1 OUT3
OUT2 OUT4
INPUT SELECT
TEMPORAL
STROBE SYNC
IN > OUT SYNC
IN1+
IN1--
IN2--
IN2+
C "DRY1" NC
RET1+
RET1--
RET2--
RET2+
C "DRY2" NC
+ OUT2 --
+ OUT3 --
+ OUT4 --
INPUT SELECT
TEMPORAL
STROBE SYNC
IN > OUT SYNC
-- AUX +
UPPER TERMINALS
LOWER TERMINALS
unswitched 120VAC
power mains
(non-power limited)
Non-Supervised
Supervised
Non-Supervised
Power-Limited Outputs
2.5 amp per output in alarm
(total= 8 amp)
(Supervised)
NC C NO
NC C NO NC C NO
AC Local
AC DELAY
BAT FAIL AC FAIL
AC LED
VR1
Ground
CAUTION: De-energize unit prior to servicing. For continued protection against
electric shock and fire hazard replace fuse with the same type and rating, 5 amp 250V.
Do not expose to rain or moisture. Use for Indoor Dry Location.
5A 250V
Fig. 2
NC CNOC "FAULT" NC
Fig. 2b
Fig. 2a
NC NO C
AC Local
Fuse
Cover
Battery 2
Battery connection (non power limited)
CAUTION: De-energize unit prior to servicing. For continued protection against risk of
electric shock and fire hazard replace fuse with the same type and rating.
Replace fuse cover before energizing. Do not expose to rain or moisture.
Battery and AC
Supervision Circuit
(power limited)
Wire Strap
(from
Enclosure
to Door)
Battery 1
Divider
Green Lead
SW1
-- DC +
SW2
+ OUT1 --
OUT1 OUT2 OUT3 OUT4
INP1 INP2
FAULT
NO "REMOTE" C
NC CNOC "FAULT" NC
RESET
OUT1 OUT3
OUT2 OUT4
INPUT SELECT
TEMPORAL
STROBE SYNC
IN > OUT SYNC
IN1+
IN1--
IN2--
IN2+
C "DRY1" NC
RET1+
RET1--
RET2--
RET2+
C "DRY2" NC
+ OUT2 --
+ OUT3 --
+ OUT4 --
INPUT SELECT
TEMPORAL
STROBE SYNC
IN > OUT SYNC
-- AUX +
UPPER TERMINALS
LOWER TERMINALS
unswitched 120VAC
power mains
(non-power limited)
Non-Supervised
Supervised
Non-Supervised
Power-Limited Outputs
2.5 amp per output in alarm
(total= 10 amp)
(Supervised)
Fig. 2c
TroubleMemory
ResetButton
Optional Hookup Diagram:
Battery 2
Battery connection (non power limited)
Battery
Supervision
and AC
Supervision
Circuit
(power limited)
Nonpower-limited
Wire Strap
(from
Enclosure
to Door)
Battery 1
Divider
Green Lead
SW1
-- DC +
SW2
+ OUT1 --
OUT1 OUT2 OUT3 OUT4
INP1 INP2
FAULT
NO "REMOTE" C
NC CNOC "FAULT" NC
RESET
OUT1 OUT3
OUT2 OUT4
INPUT SELECT
TEMPORAL
STROBE SYNC
IN > OUT SYNC
IN1+
IN1--
IN2--
IN2+
C "DRY1" NC
RET1+
RET1--
RET2--
RET2+
C "DRY2" NC
+ OUT2 --
+ OUT3 --
+ OUT4 --
INPUT SELECT
TEMPORAL
STROBE SYNC
IN > OUT SYNC
-- AUX +
UPPER TERMINALS
LOWER TERMINALS
unswitched 120VAC
power mains
(non-power limited)
Non-Supervised
Supervised
Non-Supervised
Power-Limited Outputs
2.5 amp per output in alarm
(total= 8 amp)
(Supervised)
NC C NO
NC C NO NC C NO
AC Local
AC DELAY
BAT FAIL AC FAIL
AC LED
VR1
Ground
CAUTION: De-energize unit prior to servicing. For continued protection against
electric shock and fire hazard replace fuse with the same type and rating, 5 amp 250V.
Do not expose to rain or moisture. Use for Indoor Dry Location.
5A 250V