Input:
• Input115VAC/60Hz,3.5amp.
• Inputfuserated@5amp/250V.
• FireAlarmPanelorAccessControlSystemtrigger
inputs.N.O.orN.C.supervisedtriggerinputand
polarityreversaltriggerinput.
Output:
• 12VDCor24VDCselectableoutputs.
•12VDC@4ampor24VDC@3ampsupplycurrent.
•BurglarAlarmApplications:
12VDC=10VDC-13.2VDC;
24VDC=20VDC-26.4VDC.
• Five(5)PTCprotectedClass2Ratedpowerlimited
outputs,rated@2amp.
• Outputrelayenergizeswhenunitistriggered
(form“C”contactrated1amp@28VDC).
• Filteredandelectronicallyregulatedoutput.
• Shortcircuitandthermaloverloadprotection.
Battery Backup:
• Built-inchargerforsealedleadacidor
geltypebatteries.
• Automaticswitchovertostand-bybattery
whenACfails.
• Maximumchargecurrent0.7amp.
Supervision:
• ACfailsupervision(form“C”contacts).
• Lowbatterysupervision(form“C”contacts).
• Batterypresencesupervision(form“C”contacts).
• Powerfailsupervisionrelay(form“C”contacts).
Visual Indicators:
• ACinputandDCoutputLEDindicators
(powersupplyboard).
• RedLEDsindicateconditionofpoweroutputs
(multi-outputboard).
• Power&inputtriggerLEDs(multi-outputboard).
Electrical:
• Operatingtemperature:0ºCto49ºCambient.
•BTU/Hr.:
-12VDC:24.57BTU/Hr.
-24VDC:36.85BTU/Hr.
• SystemACinputVArequirement:402.5VA.
Mechanical:
• EnclosureDimensions(HxWxDapprox.):
13.5”x13”x3.25”(342.9mmx330.2mmx82.55mm)
- Accommodatesuptotwo(2)12VDC/7AHbatteries.
• Productweight(approx.):7.6lbs.(3.45kg).
• Shippingweight(approx.):8.6lbs.(3.9kg).
Specifications
Agency Approvals
Altronix Corp.
140 58th St. Brooklyn, NY
ULListedforAccessControlSystemsUnits
(UL294).
ULListedStandardforPowerSuppliesforUse
withBurglar-AlarmSystemUnits(UL603).
ULListedHospitalSignalingandNurseCall
Equipment(UL1069).
ULListedStandardforSafetyforFire
ProtectiveSignalingSystems(UL1481).
AL400ULMR
Multi-Output Power Supply/Charger
Rev.DSAL400ULMR-07112013
AL400ULMRmulti-outputaccesscontrolpowersupply/chargerisspecifically
designed for use with access control systems and accessories. This unit con-
vertsa115VAC/60Hzinputintofive(5)individuallyprotectedClass2Rated
powerlimited12VDCor24VDCoutputs.Eachoutputwillroutepowertoava-
rietyofaccesscontrolhardwaredevicesincludingMagLocks,ElectricStrikes,
MagneticDoorHolders,etc.TheseoutputswilloperateinbothFail-Safeand
Fail-Securemodes.Controlledtriggerinputisachievedthroughnormallyopen
(N.O.)ornormallyclosed(N.C.)supervisedinputorthepolarityreversalfrom
an FACP (Fire Alarm Control Panel). A form “C” dry output relay enables
HVACShutdown,ElevatorRecalloritmaybeusedtotriggerauxiliarydevices.
CSFM-CaliforniaStateFire
MarshalApproved.
MEA- NYCDepartmentof
BuildingsApproved.