Spec Sheet
AL125UL Series
Power Supply/Chargers
Input
Voltage Varies, See Reference Chart.
Outputs
Voltage 12VDC or 24VDC selectable.
Current 1A power-limited continuous max.
Protection PTC.
Other Filtered and regulated.
Back-up Battery (not included)
Capacity Varies, See Reference Chart.
Type Sealed lead acid or gel type.
Failover Upon AC loss, instantaneous.
Indicator (LED)
Unit Status Normal / No Output / Loss of AC / Triggered.
Agency Listings
Access Control UL294
CSA Standard C22.2 No.205-M1983,
Signal Equipment.
NYC Department of Buildings Approved
Physical and Environmental
Dimensions (H x W x D) and Description
AL125UL (power supply, transformer, cam lock, and enclosure):
AL125ULP (power supply, 24VAC/40VA plug-in transformer,
cam lock, and enclosure):
AL125ULE (power supply, cam lock, and enclosure):
8.5” x 7.5” x 3.5” (215.9mm x 190.5mm x 88.9mm).
AL125ULX (power supply, transformer, cam lock, and enclosure):
13.5” x 13” x 3.25” (342.9mm x 330.2mm x 82.55mm).
Product Weight / Shipping (approx.)
Model Product Weight Shipping Weight
AL125UL 5.1 lbs. (2.31 kg) 5.6 lbs. (2.54 kg)
AL125ULP 6.3 lbs. (2.86 kg) 6.8 lbs. (3.08 kg)
AL125ULE 3.3 lbs. (1.50 kg) 3.8 lbs. (1.72 kg)
AL125ULX 9.5 lbs. (4.31 kg) 10.4 lbs. (4.72 kg)
Temperature
Operating 0ºC to 49ºC (32ºF to 120ºF).
Storage -20ºC to 70ºC (-4ºF to 158ºF).
Relative Humidity 85% +/-5%.
BTU/Hr. (approx.):
12VDC: 6 BTU/Hr.
24VDC: 6 or 12 BTU/Hr.
Altronix Corporation | 140 58th St | Brooklyn, NY 11220 USA
phone: +1 718.567.8181 | fax: +1 718.567.9056 | email: info@altronix.com | www.altronix.com
Specifications