nstallation Instructions

- 8 - AL1042ULADA
OUT1
OUT2 OUT3 OUT4
INP2 INP1
FAULT
RESET
OUT1 OUT3
OUT2
OUT4
IN>OUT SYNC
STROBE SYNC
TEMPORAL
INPUT SELECT
IN>OUT SYNC
STROBE SYNC
TEMPORAL
INPUT SELECT
NC C NO C "FAULT" NC
+ DC ---
-- AUX2 +
-- LOOP4 +
-- OUT4 +-- OUT3 +
-- LOOP3 + -- LOOP1 +
-- OUT1 +-- OUT2 +
-- LOOP2 +
-- IN1 +
-- RET1 +
-- IN2 +
-- RET2 +
NC "DRY1" C
NC "DRY2" C
-- AUX1 +
Addressable
control module
trigger output
(See Typical Application Diagram for device hookup)
Power-Limited Outputs 2.5 amp per output max. (total = 10 amp)
+ --
4-wire Smoke
Detector
+ --
4-wire Smoke
Detector
Fire
Alarm
Control
Panel
(FACP)
EOL Power
Supervision Relay
(Not Supplied)
EOL Resistor
from FACP
Digital Communicator
or Local Annunciator
Dry output Contact
(Form "C" contacts)
These circuits are used to
monitor AC and Bat Fail
and will cause a
simultaneous trouble
condition to the FACP's
IN1 and IN2
(Non-Supervised)
Factory Installed Board
Interface Cable
AC
Magnetic
Door Holder
stand-by battery
connection
(non power-limited)
BAT FAIL
AC FAIL
+ BAT –+ DC --
DC AC
AC DELAY
NC C NO NC C NO
AC LOCAL
NC C NO
L
N
Battery and AC Supervision
Circuit (power-limited).
Use separate knockout.
6.3A 250V
15
15A 32V
line
neutral
unswitched
120VAC
power mains
(non power-limited)
Optional hookups:
1- BatteryandACmonitoring:ACorBatteryFailconditionwillcausethecommontroubleinput[C“FAULT”NC]to
reportbacktotheFACPviainput1andinput2.Thecommontroubleinputmayalsobeusedforotheroptional
supervisorymonitoring.
ToreportACandBatteryTroubleconnectthebatteryandACFailrelayoutputshowninFig. 3a, pg. 8tothe
commontroubleinput.
2- Drycontactinput(C“DRY1”NC)(C“DRY2”NC)canbeusedtoalarmoutputfroman
addressablemodule(theseinputsareunidirectionandcannotreportbacktotriggermodule).
Connection to triggering devices must be made within 20ft. of distance and using conduit for wiring.
3- Auxiliaryoutput(-AUX+)24VDCat1ampmax.
4- ACLocal[NC,NO,C]shouldconnecttothehostcontrolpanelforlocalannunciationofthetroublecondition.
Note: Ifcommontroubleinput,terminalsmarked[C“FAULT”NC]arenotused,theseterminalsmustbe
shorted(connectjumper)toremaininactive.ForoptionalhookupsseeFig. 3b, pg. 8.
Optional Hookup Diagram:
Fig. 3 Fig. 3a
Fig. 3b
Fig. 3c
Maintenance:
Unitshouldbetestedatleastonceayearfortheproperoperationasfollows:
Output Voltage Test:Undernormalloadconditions,theDCoutputvoltageshouldbecheckedforpropervoltagelevel
(26.2-26.4VDC recommended range).
Battery Test:Undernormalloadconditionscheckthatthebatteryisfullycharged.Checkspecifiedvoltage
bothatbatteryterminalandattheboardterminalsmarked[+BAT--]toensurethatthereisnobreakinthebattery
connectionwires.
Fuses:Checkinputandoutputfusesonthepowersupplyboard,replaceifnecessary.
Inputfuseratingis6.3amp@250V,Outputfuseratingis15amp@32V.
Note:Maximumchargingcurrentis1.5amp.
Note:Expectedbatterylifeis5years;however,itisrecommendedchangingbatteriesin4yearsorlessifneeded.
OUT1
OUT2 OUT3 OUT4
INP2 INP1
FAULT
RESET
OUT1 OUT3
OUT2
OUT4
IN>OUT SYNC
STROBE SYNC
TEMPORAL
INPUT SELECT
IN>OUT SYNC
STROBE SYNC
TEMPORAL
INPUT SELECT
NC C NO C "FAULT" NC
+ DC ---
-- AUX2 +
-- LOOP4 +
-- OUT4 +-- OUT3 +
-- LOOP3 + -- LOOP1 +
-- OUT1 +-- OUT2 +
-- LOOP2 +
-- IN1 +
-- RET1 +
-- IN2 +
-- RET2 +
NC "DRY1" C
NC "DRY2" C
-- AUX1 +
Addressable
control module
trigger output
(See Typical Application Diagram for device hookup)
Power-Limited Outputs 2.5 amp per output max. (total = 10 amp)
+ --
4-wire Smoke
Detector
+ --
4-wire Smoke
Detector
Fire
Alarm
Control
Panel
(FACP)
EOL Power
Supervision Relay
(Not Supplied)
EOL Resistor
from FACP
Digital Communicator
or Local Annunciator
Dry output Contact
(Form "C" contacts)
These circuits are used to
monitor AC and Bat Fail
and will cause a
simultaneous trouble
condition to the FACP's
IN1 and IN2
(Non-Supervised)
Factory Installed Board
Interface Cable
AC
Magnetic
Door Holder
stand-by battery
connection
(non power-limited)
BAT FAIL
AC FAIL
+ BAT –+ DC --
DC AC
AC DELAY
NC C NO NC C NO
AC LOCAL
NC C NO
L
N
Battery and AC Supervision
Circuit (power-limited).
Use separate knockout.
6.3A 250V
15
15A 32V
line
neutral
unswitched
120VAC
power mains
(non power-limited)
NC C NO C "FAULT" NC
TroubleMemory
ResetButton
+ DC ---
BAT FAIL
NO C NC NO C NC
+ BAT ---
L G N
DC
AC FAIL
AC
15A
32V
10A
250V
OUT1
OUT2 OUT3 OUT4
INP2 INP1
FAULT
RESET
OUT1 OUT3
OUT2
OUT4
IN>OUT SYNC
STROBE SYNC
TEMPORAL
INPUT SELECT
IN>OUT SYNC
STROBE SYNC
TEMPORAL
INPUT SELECT
NC C NO C "FAULT" NC
+ DC ---
-- AUX2 +
-- LOOP4 +
-- OUT4 +-- OUT3 +
-- LOOP3 + -- LOOP1 +
-- OUT1 +-- OUT2 +
-- LOOP2 +
-- IN1 +
-- RET1 +
-- IN2 +
-- RET2 +
NC "DRY1" C
NC "DRY2" C
-- AUX1 +
Green Lead
Addressable
controlmodule
triggeroutput
(See Typical Application Diagram for device hookup)
Power-Limited Outputs 2.5 amp per output max.
(total = 10 amp)
+ --
4-wire Smoke
Detector
+ --
4-wire Smoke
Detector
Fire
Alarm
Control
Panel
(FACP)
EOL Power
Supervision Relay
(Not Supplied)
EOL Resistor
from FACP
Digital Communicator or
Local Annunciator Dry
output Contact
(Form "C" contacts)
These circuits are used to monitor
AC and Bat Fail and will cause a
simultaneous trouble condition
to the FACP's IN1 and IN2
(Non-Supervised)
Factory Installed
Board Interface
Cable
AC
Fuse
Cover
unswitched 115VAC
50/60Hz, 4.4 amp
power mains
(non power-limited)
Magnetic
Door Holder