Description
Altronix ACMS8 and ACMS8CB dual input design allows power to be steered from two (2)
independent low voltage 5 to 24 VDC power sources into eight (8) independently controlled
fuse or PTC protected outputs. In ACMS8, these power outputs can also be converted to dry
form “C” contacts. Outputs are activated by an open collector sink, normally open (NO) or
normally closed (NC) dry trigger input from an Access Control System, Card Reader, Keypad,
Push Button, PIR, etc. ACMS8/ACMS8CB will route power to a variety of access control hard-
ware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will
operate in both Fail-Safe and/or Fail-Secure modes. The FACP Interface enables Emergency
Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm
disconnect feature is individually selectable for any or all of the eight (8) outputs. The spade
connectors allow you to daisy chain power to multiple ACMS8/ACMS8CB modules. This
feature allows you to distribute the power over more outputs for larger systems.
ACMS8 and ACMS8CB
Multi-Output Access Power Controllers
Rev. ACMS8 Series 09112018
ACMS8
Input
Voltage Range
ACMS8: 5VDC to 24VDC, up to 10A each or
20A total input.
ACMS8CB: 5VDC to 24VDC up to 10A each or
16A total input.
Current 0.6A @ 12V, 0.3A @ 24V
Consumption: with all relays energized.
Main Fuse Rating 10/32A.
Trigger Inputs:
Eight (8) individually controlled trigger inputs:
a) Normally open (NO) inputs.
b) Normally closed (NC) inputs.
c) Open collector sink inputs.
d) Wet Input (5VDC - 24VDC) with 10K resistor.
e) Any combination of the above.
Outputs
ACMS8: Fuse protected outputs rated @ 2.5A per output,
non power-limited. Total output 20A max.
Do not exceed the individual power supply ratings.
ACMS8CB: PTC protected outputs rated @ 2A per output,
Class 2 power-limited. Total output 16A max.
Do not exceed the individual power supply ratings.
Eight (8) selectable 5VDC - 24VDC independently controlled
outputs or eight (8) indepently controlled Form “C” relay outputs:
a) Fail-Safe and/or Fail-Secure power outputs.
b) Form “C” Relays. 28VAC or VDC @ 2.5A Rated.
c) Auxiliary power outputs (unswitched).
d) Any combination of the above.
Any of the eight (8) fuse protected power outputs are selectable
to follow power Input 1 or Input 2.
Individual outputs may be set to OFF position for servicing.
Output Ratings:
ACMS8: Fuses are rated 2.5A each.
ACMS8CB: PTCs are rated 2A each.
Total output current is determined by the power supply(ies),
not to exceed a maximum of 10A for each input.
Fire Alarm Disconnect
Supervised Latching or non-latching, individually
selectable for any or all of the eight (8) outputs.
EOL 10K Resistor.
Indicators (LED)
Red LEDs Outputs are triggered (relays energized).
Blue LED FACP disconnect is triggered.
Individual voltage LEDs
Green: 12VDC
Red/Green: 24VDC.
Physical and Environmental
Dimensions (W x L x H)
7.65” x 4.125” x 1.25” (194.3mm x 104.8mm x 31.8mm).
Product Weight 0.7 lb. (0.32 kg).
Shipping Weight 0.95 lb. (0.43 kg).
Temperature
Operating 0ºC to 49ºC (32ºF to 120ºF).
Storage -20ºC to 70ºC (-4ºF to 158ºF).
Relative Humidity 93% +/-5%.
BTU/Hr. (approx.): 4 BTU/Hr.
Specifications