Data Sheet

ACM4CBE
Multi-Output Access Power Controllers
Rev. DSACM4CBE_06192014
ACM4CBE converts one (1) 12 to 24 volt AC or DC input into four (4) inde-
pendently controlled PTC protected outputs. Outputs are activated by an open
collector sink or normally open (NO) dry trigger input from an Access Control
System, Card Reader, Keypad, Push Button, PIR, etc. The ACM4ECB will route
power to a variety of access control hardware devices including Mag Locks,
Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-
Safe and/or Fail-Secure modes.
Units are designed to be powered by one common power source which will pro-
vide power for both the board operation and locking devices, or two (2) totally
independent power sources, one (1) providing power for board operation and
the other for lock / accessory power. The FACP Interface enables Emergency
Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices.
The fire alarm disconnect feature is individually selectable for any or all of the
four (4) outputs.
Overview
Specifications
Agency Approvals
UL File # BP6714
UL Listed for Access
Control System Units (UL 294).
UL File # BP6714 - UL Listed
for Access Control System Units
(UL 294). “Signal Equipment”
Evaluated to CSA Standard C22.2
No.205-M1983
UL Listed
Sub-Assembly.
UL Listed
Accessory.
ACM4CBE
Input:
• 12to24voltACorDCoperation
(setting not required), (0.4 amp @ 12volt,
0.2 amp @ 24 volt current consumption with all
relays energized).
• Powersupplyinputoptions:
a) One (1) common power input
(board and lock power).
b) Two (2) isolated power inputs (one (1) for
board power and one (1) for lock/accessory power).
• Four(4)AccessControlSystemtriggerinputs:
a) Four (4) normally open (NO) inputs.
b) Four (4) open collector sink inputs.
c) Any combination of the above.
Output:
• Four(4)independentlycontrolledoutputs:
a) Four (4) Fail-Safe and/or Fail-Secure
power outputs.
b) Four (4) dry form “C” 5 amp rated relay outputs
• Outputratings:
- PTCs are rated 3 amp each.
- Main fuse is rated at 10 amp.
Note:Totaloutputcurrentisdeterminedbythe
power supply, not to exceed a maximum
of 10 amp total.
Features:
• FireAlarmdisconnect(latchingornon-latching)is
individually selectable for any or all of the
four (4) outputs.
• FireAlarmdisconnectinputoptions:
a) Normally open (NO) or normally closed (NC) dry
contact input.
b) Polarity reversal input from FACP signaling circuit.
• FACPoutputrelay(form“C”contactrated@1amp
28VDC not evaluated by UL).
• Removableterminalblocksfacilitateease
of installation.
Visual Indicators:
• RedLEDsindicateoutputsaretriggered
(relays energized).
• GreenLEDindicatesFACPdisconnectistriggered.
Electrical:
• Operatingtemperature:0ºCto49ºCambient.
• BTU/Hr.:
- 12VDCor12VAC:1.22BTU/Hr.
- 24VDCor24VAC:2.46BTU/Hr.
Mechanical:
• EnclosureDimensions(HxWxDapprox.):
8.5” x 7.5” x 3.5” (215.9mm x 190.5mm x 88.9mm)
• Productweight(approx.):7lbs.(3.175kg).
• Shippingweight(approx.):7.6lbs.(3.45kg).

Summary of content (2 pages)