Technical data
Working range (typical) ...............................................................................................up to 500ft (150m)
Measuring accuracy
“Fine” adjustment, approx ....................................................................................................... ±1.5mm
“Medium” adjustment, approx ......................................................................................................±3mm
(
Results may vary depending on laser and environmental differences.)
Operating temperature ...................................................................................................... 32°F – 122°F
(0°C – +50°C)
Storage temperature ..........................................................................................................-4°F – 158°F
(–20°C – +70°C)
Battery .............................................................................................................................1 x 9 V 6LR61
Battery Life, approx. ......................................................................................................... 30hrs (typical)
Weight ......................................................................................................................... 0.75lb (0.34 kg)
Dimensions .....................................................................................................................5” x 2.25” x 1”
(131 x 57 x 29mm)
1) The working range can be decreased by unfavorable environmental conditions (e.g. direct sun
irradiation).
Please observe the article number on the type plate of your tool. The trade names of the individual
tools may vary.
The tool can be clearly identified with the serial number 12 on the type plate.
Technical Data
Operation
Initial Operation
•Protectthetoolagainstmoisture.
•Do not subject the tool to extreme
temperatures or variations in temperature.
As an example, do not leave it in vehicles
for longer periods. In case of large variations
in temperature, allow the tool to adjust to the
ambient temperature before putting it into
operation. In case of extreme temperatures or
variations in temperature, the accuracy of the tool
can be impaired.
Setting Up the Tool (see figure A)
Position the tool at least 3ft (1m) away from the
rotary laser. Switch on the rotary laser, and select
horizontal or vertical operation.
Position the tool in such a manner that the laser
beam can reach the reception area 6. Align the
tool in such a manner that the laser beam runs
laterally through the reception area (as shown in
the figure).
Switching On and Off
• A loud audio signal sounds when
switching on the tool.
Therefore, keep the tool away from your ear
or other person when switching on. The loud
audio signal can cause hearing defects.
To switch on the tool, press the On/Off button
2. All LEDs light up briefly and an audio signal
sounds.
To switch off the tool, press the On/Off button
2 again. Before switching off, all LEDs briefly light
up.
When no button is pressed on the tool for
approx. 6 minutes and when no laser beam
reaches the reception area 6 for 6 minutes, the
tool automatically switches off in order to save
the battery. The switching off is indicated by brief
lighting up of all LEDs.
- 7 -