PROCESSING FREEZER / CHILLER / REFRIGERATION SYSTEM Model: QC2-3 QC2-20 QC2-40 QC2-100 QC2-100 remote (shown QC2-100 with roll-in cart) QC2-40 • Installation • Operation QC2-20 QC2-3 • Maintenance W164 N9221 Water Street • P.O. Box 450 • Menomonee Falls, Wisconsin 53052-0450 USA PHONE: 262.251.3800 • 800.558.8744 usa / Canada FAX: 262.251.7067 • 800.329.8744 u . s . a . www.alto-shaam.com printed in u.s.a. OnLY MN-36580 (Rev.
Delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Safety Procedures and Precautions. . . . . . . . . . . . . . . . . 2 Installation Site Installation. . . . . . . . . . . . . . . . . . . . . . . Clearance Requirements. . . . . . . . . . . . . . . .
DelIVery UnpackIng This Alto-Shaam appliance has been thoroughly tested and inspected to insure only the highest quality unit is provided. Upon receipt, check for any possible shipping damage and report it at once to the delivering carrier. See Transportation Damage and Claims section located in this manual. This appliance, complete with unattached items and accessories, may have been delivered in one or more packages.
SafeTy proceDUreS anD precaUTIonS Knowledge of proper procedures is essential to the safe operation of electrically and/or gas energized equipment. In accordance with generally accepted product safety labeling guidelines for potential hazards, the following signal words and symbols may be used throughout this manual. Danger Used to indicate the presence of a hazard that WILL cause severe personal injury, death, or substantial property damage if the warning included with this symbol is ignored.
i n st a l l a ti o n Danger IMPROPER INSTALLATION, ALTERATION, ADJUSTMENT, SERVICE, OR MAINTENANCE COULD RESULT IN SEVERE INJURY, DEATH, OR CAUSE PROPERTY DAMAGE. READ THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT. caUTIon TO PREVENT PERSONAL INJURY, USE CAUTION WHEN MOVING OR LEVELING THIS APPLIANCE. 5-Year Limited Warranty on self-contained compressor Effective from date of shipment.
i n st a l l a ti o n sit e i n st a l l a ti o n INS T ALLA T I ON RE Q UIRE MEN TS The model QC2-3 is a counter mounted unit and must use legs that allow for a 4" (102mm) clearance between the cabinet and the counter. For all other models, install the appliance on a smooth and level floor surface. Use the adjustable cabinet legs to level the Quickchiller.
i n st a l l a ti o n L e g i nsta l l a ti o n - Q C2 - 1 0 0 1. A voiding trolley guides and drain, carefully lift unit off of floor with forklift just high enough to fit leg assembly a and tools. 51mm sit e i n st a l l a ti o n 2. Pound feet b into frame a. 51mm 3. A lign frame with holes on the bottom of the unit. Insert screws d through nut inserts c and attach to frame using a 3/8" socket. 4. Adjust feet accordingly to level the unit.
i n st a l l a ti o n sit e i n st a l l a ti o n Adj ust a b l e hing es Hinges can be modified for a left or right-hand door. 1. R emove hinge cover a. 2. Remove screws from hinge b. 3. Remove metal cap c. 4. I nsert flat screwdriver into slot and pry out d. Rotate cam so that deep grove is positioned to the right for left‑hand hinge, or left for right-hand hinge e. 5. L ock metal cap back into place. Replace screws, and hinge cover. a Left-Hand Hinge Position b c d QUICKCHILLER • MN-36580 (REV.
i n sttit a l llaeti o n sube tit sit i n st l ea l l a ti o n QC2-3 55-3/4" (1416mm) 5" (127mm) Electrical Connection Cord Length: 9' (2743mm) 38" (965mm) 30" (762mm) 4" (102mm) 27" (686mm) weig ht pr o du ct\pa n ca pa city net : contact factory carton dimensions : ( l ship : Approximately 36 lb (16 kg) 330 lb (150 kg) volume maximum : x w x h) 35" x 35" x 42" (889mm x 889mm x 1067mm) r efri g e r atio n 40 oz.
I N S Ttit ALLA l eT I O N sube tit sit i n st l ea l l a ti o n 36" (914mm) 60" (1524mm) QC2-20 36" (914mm) 42" (1067mm) 36" (914mm) 57" (1448mm) weig ht pr o du ct\pa n ca pa city net : contact factory carton dimensions : ( l ship : 450 lb (204 kg) x w x h) 60" x 39" x 48-1/2" (1524mm x 991mm x 1232mm) r efri g e r atio n 40 oz.
I N S Ttit ALLA l eT I O N sube tit sit i n st l ea l l a ti o n QC2-40 32-7/8" (835mm) 60" (1524mm) 7" (178mm) Electrical Connection Cord Length 9 ft (2743mm) 3/4" (19mm) 36" (914mm) 40" (1016mm) 71" (1803mm) 35-1/8" (892mm) 6-1/2" (165mm) weig ht ( e s t . ) net : pr o du ct\pa n ca pa city 654 lb (297 kg) carton dimensions : ( l ship : 815 lb (370 kg) x w x h) 55-1/2" x 45-1/4" x 87" (1410mm x 1149mm x 2210mm) r efri g e r atio n 80 oz.
I N S Ttit ALLA l eT I O N sube tit sit i n st l ea l l a ti o n QC2-100 15-1/2" (394mm) Hinged Left 35-1/2" (902mm) Hinged Right 17-5/8" (447mm) 14" (355mm) 76" (1930mm) 35-1/2" (902mm) Electrical Connection Condensate Drain 1-1/2" (38mm) 42" (1067mm) 39" (991mm) 36" (914mm) 86" (2184mm) 96-3/4" (2457mm) 65" (1651mm) 51" (1295mm) 10-3/4" (273mm) weig ht ( e s t .
I N S Ttit ALLA l eT I O N sube tit sit i n st l ea l l a ti o n QC2-100R 76" (1930mm) 35-1/2" (902mm) 14" (355mm) 17-5/8" (447mm) 15-1/2" (394mm) Hinged Left 35-1/2" (902mm) Hinged Right Electrical Connection Condensate Drain 1-1/2" (38mm) 42" (1067mm) 39" (991mm) weig ht QC2-100R Pan Cart net : contact factory net : Plate Cart 120 lb (54 kg) net : contact factory carton dimensions : ( l ship : contact factory ship : 161 lb (73 kg) ship : contact factory x w x h) 57" x 44" x 93" (1448m
I N S Ttit ALLA l eT I O N sub o p ti o tit n sl ea n d a c c e ss o r i e s QC2-3 QC2-20 QC2-40 QC2-100 QC2-100R 5014890 — — — 5014751 5014751 5014751 — 5014889 — — — 5014891 — — — Prechill Sealing Strip — — — SA-35079 Roll-in Pan Cart 20 shelf pan trolley - Fits 20-20e, 20-20g, 20-20mw, and QC2-100 69-1/2" x 26-7/8" x 34-1/2" (1766 x 683 x 877mm) 2-9/16" (65mm) vertical spacing between shelves — — — 5014652 5017147 (ci) — — — — — — — — — 5016480 5017151 (ci) model >
i n sttit a l llaeti o n sub e l e ctit t r ilcea l This appliance must be branch circuit protected with proper ampacities, in accordance with the wiring diagram. The Quickchiller must be properly grounded in accordance with the National Electrical Code and applicable local codes. Wire size for the main incoming power to the unit must match the minimum size listed in the specifications applicable to the specific Quickchiller model. For supply connections, locate the wire size listed in this manual.
Ope tit r alti e on OPERA TI NG INT RODUCT ION The Alto-Shaam ® Quickchiller ™ is a processing refrigeration system designed to rapidly and uniformly decrease the temperature of hot foods to either a chilled or frozen state. This process provides enhanced safety, longer storage life and better production efficiency.
Ope tit r alti e on CHILL PROCESSING CYCLES Quickchiller Operation Modes The Alto-Shaam Quickchiller uses high velocity cold air circulation to remove heat from prepared foods for the purpose of rapidly reducing temperatures through the danger zone and providing maximum storage life. Cold air is evenly directed across each pan from the control side of every Quickchiller model to assure rapid cooling.
Ope tit r alti e on Additional information DOOR ➤ Clean the Quickchiller and probes prior to use and make certain all processing modes are operating properly before chilling or freezing foods. If the QC2-40 or QC2-100 door is opened during any running chill or freeze cycle, the fans will disengage, and a “DOOR IS OPEN” message will appear on the screen. If the door is open for longer than 2 minutes, a beeper will sound.
O p e r a ti o n T O U CH SC R E EN ME NUS Home Professional Mode Recipes Sleep Mode Toolbox Download HACCP Download Download Recipes Settings Upgrade Software Service Farenheit/Celcius Error Codes Manual Defrost E-10 E-11 P-10 P-20 P-30 C-10 C-11 E-80 E-84 E-83 E-53 E-54 E-66 E-77 E-70 E-94 HMI: 01.00H ID: 01:A5:FF:FF:FF:FF RB: 00.
Ope tit r alti e on sub o p e rtit a tilneg i n st r u c ti o n s Chill using preset Recipes Quickchiller > Preset Recipes 1. 2. 3. 4. Touch Touch screens. to view recipes. or to move between recipe Select desired recipe. Touch to start chill cycle. The screen will indicate: -C hill Time - The length of time the chiller is operating in the preset mode. -C hill Temperature - The preset temperature. - Probe Temperature - The temperature of all food probes. Touch Mode Chill Probe Hold 1.
O p e r a ti o n CH I L L MO D E S soft chill … To rapidly decrease the temperature of foods by internal product probe temperature or time within a range of 24°F to 36°F (-4°C to 2°C). Soft Chill is recommended for less dense food items that chill quickly. The mode automatically converts to a refrigerated holding temperature at the end of the chill cycle. Use Soft Chill for less dense items such as fish or vegetables.
Ope tit r alti e on sub o p e rtit a tilneg i n st r u c ti o n s Professional Mode - Chill Mode Touch on Home screen. Soft Chill Hard Chill Quick Freeze 1. Choose desired Chill mode 2. Touch 4. Enter desired Chill time or Probe temperature on number pad, or touch 5. Touch 6. Touch to adjust Temperature, and are the last used settings. 7. Enter desired time or temperature on number pad, or touch 8. Touch 9. Touch to Chill by Time, or to enter or to Chill by Probe.
Ope tit r alti e on sub o p e rtit a tilneg i n st r u c ti o n s Professional Mode - Hold Mode Touch on Home screen. 1. Touch Hold 2. Enter Hold temperature on number pad, or touch 3. Touch to select factory default. to retun to settings screen, or touch to start the Hold cycle. The screen will indicate: - C hill Time - The length of time the chiller is operating in the preset mode. - C hill Temperature - The preset temperature.
Ope tit r alti e on sub o p e rtit a tilneg i n st r u c ti o n s Downloads Toolbox Download HACCP Download Download Recipes Upgrade Software HACCP 1. Insert USB data stick into data port on front of the unit. 2. Touch and then . Screen will show the HACCP file that is being copied and will display any errors that occure while the file is downloading. When "Done" is displayed, transfer is complete. Pull the data stick out of the data port.
Ope tit r alti e on sub o p e rtit a tilneg i n st r u c ti o n s Downloads ( continued ) Download Recipes 1. Insert USB data stick into data port on front of the unit. 2. Touch and then . 3. Display will indicate that a download is in process. When complete, pull the data stick out of the data port. Screen will return to Home screen. Note: Download cannot be done when QC2 is in chill mode. Software Upgrade 1. Insert USB data stick into data port on front of the unit. 2. Touch and then .
Ope tit r alti e on sub o p e rtit a tilneg i n st r u c ti o n s Settings Farenheit/Celcius Manual Defrost Defrost Frequency Probe Calibration Settings Date/Time Screen Brightness Default Hold Temperature Defrost Duration Drip Time Probe Count Factory Pressets Screen Calibration Alarm Demo Mode to choose Farenheit or Celcius for Quickchiller screen readings. ºF/ºC - Touch to begin defrost cycle. Screen will display defrost duration and drip time.
Ope tit r alti e on sub o p e rtit a tilneg i n st r u c ti o n s Settings ( continued ) Hold default - Touch and enter default hold temperature between -5 to +40 (-21C to +4C) on number pad or select factory default Defrost time - Touch . . This is the amount of time the defrost function will run before automatically switching back to the chilling mode. Factory default setting is 20 minutes. Use or to adjust the duration of defrost within a range of 10-30 minutes.
Ope tit r alti e on sub o p e rtit a tilneg i n st r u c ti o n s Service HMI: 01.00H ID: 01:A5:FF:FF:FF:FF RB: 00.86 Compile Date: 04/01/2014 16:00 Cavity Probe 1 Probe 2 Probe 3 Coil Service 0ºF 0ºF 0ºF 0ºF 0ºF Door Defrost In Touch to view Service settings. 00:00:00 Defrost 0000:00:00:00 Drain Heater 0000:00:00:00 Fan 0000:00:00:00 Solenoid 0000:00:00:00 Error Codes E-10 E-11 P-10 P-20 P-30 C-10 C-11 E-80 E-84 E-83 E-53 E-54 E-66 E-77 E-70 E-94 Error Codes Touch to view error codes.
Ope tit r alti e on sub o p e rtit a tilneg i n st r u c ti o n s Error Message If an error occurs, will appear on screen, along with the error code. Touch to acknowledge error. Refer to error codes in this manual. E-10 Error Code Touch to acknowedge error code Power Outage If a power failure occurs, the control will produce an audible signal every 10 seconds and the display will indicate the amount of time the power was off. Timer will stop accumulating once 24 hours is reached.
Ope tit r alti e on Food Probe Use Unpacking Food Probes 1. Cut and remove the plastic ties keeping the probe cables coiled during shipment. When removing the ties, exercise caution to avoid accidentally cutting the black plastic covers on the probe cable wires. 2. Uncoil the probe cables and insert the metal portion of each probe into the bracket mounted on the inside of the cabinet. Proper probe placement is in the following sequence: Place the top probe (Product Probe 1) in the top bracket.
Ope tit r alti e on sub Dtit FOO HAN l e D L I NG G U I D EL I NE S P r oduct c o vering PORTI ONI NG & PACKAGI NG To maintain sanitation control when loading the Quickchiller, foods should be above 140°F (60°C) and should be tightly covered. A tight cover is an important part of proper chilling methods and must be used to prevent the possibility of accidental contamination by airborne bacteria. 1.
Ope tit r alti e on Q uick chi l l er Pa n Ca pa cit y: The following Quickchiller Capacity Chart indicates the number of pans that can be accommodated in the appropriate size chiller for the chilling or freezing function. Additional pans can be accommodated only when using the Quickchiller for holding at a refrigerated temperature or at a maintenance temperature for frozen food. DO NOT OVERLOAD THE QUICKCHILLER FOR THE PROCESSING FUNCTION. c h i l l i n g PAN C a p a c it y CHAR T chiller no .
Ope tit r alti e on the following chart of portion sizes and SERVING capacitY PER PAN IS PROVIDED as a general reference ONLY.
care an tit d l ce leaning cleanIng anD preVenTaTIVe MaInTenance proTecTIng STaInleSS STeel SUrfaceS It is important to guard against corrosion in the care of stainless steel surfaces. Harsh, corrosive, cleanIng agenTS Use non-abrasive cleaning products designed for use on stainless steel surfaces. Cleaning agents must be chloride-free compounds and must not or inappropriate chemicals can completely destroy the contain quaternary salts.
care an tit d l ce leaning Interior Cleaning Probe Cleaning Procedures Remove the optional roll-in cart (trolley) from cart equipped models. Open the Quickchiller door to warm the interior of the cabinet. 1. Remove all food soil from probes between loads and at the end of each production shift. Wipe entire probe, cable assembly, and probe holding door bracket with warm detergent solution and a clean cloth. 2. Remove detergent by wiping each probe, cable, and bracket with clean rinse water and a cloth. 3.
t r o ub l e s h o o ti n g Error code Action Required E-10 – Cavity Sensor Shorted This error message indicates a problem with the interior cavity sensor. The Quickchiller will not operate in any operational mode. Call service. E-11 – Cavity Sensor Open This error message indicates a problem with the interior cavity sensor. The Quickchiller will not operate in any operational mode. Call service. P-10 – Probe 1 shorted This error message indicates a problem with the Probe 1.
parts information QC2-3 Bottom 12 13 14 11 1 10 2 9 5a 5b 8 7 4 5a 3 5b 6 Item 1 2 3 4 5a 5b 6 7 8 9 10 11 12 13 14 Part RE-29821 PE-29819 PE-29830 SW-29823 5014889 LG-29904 SC-29824 CS-29822 CS-29822 SC-29824 SC-29824 BX-29820 SC-29829 FU-29901 PN-29825 EL-29828 NU-29827 BT-29826 CD-29831 Description Condensing Unit Duct Top Louver Channel Compressor Louver Pressure Switch Leg Assembly (Set of 4) Leg, 6" Bolt, 1/4" .
parts information QC2-3 Box view 1 11 2 4 20 3 7 5 19 6 8 18 17 4 16 9 15 10 14 Item 1 2 3 4 5 6 7 8 9 10 11 Part BT-29841 PR-35771 PR-36201 SR-29832 BU-29937 SC-29839 GS-29838 DR-29833 HG-35736 PI-35930 SC-29835 Description Holding Bracket Ref Line Probe Receptacle Assembly Probe, Quick Connect Stainless Steel Side Rack Bushing, Nylon Hinge 118 Screw, 10x1/2" Slot Gasket, 15.59 x 24.
parts information QC2-3 coil view 1 2 3 4 5 8 7 6 9 6 Add plastic edge guard to drip pan 15 16 Item 1 2 3 4 5 6 7 8 Part GD-29848 GD-29850 FA-29854 FA-29853 SC-29855 BT-29847 VA-29852 RE-29846 Description Qty.
parts information QC2-3 Compressor view 2 3 1 4 5 11 10 9 8 7 6 5 Item 1 2 3 4 5 6 7 8 9 10 11 Part RE-29861 SW-29823 FI-29862 ** VA-29863 ** ** VA-29864 MO-29865 FA-29866 ** Description Condensing Assembly, 1/2 MED R404A 120V Pressure Switch Dryer, 1/4" Filter with 2nd 1/4" Service Valve King Solenoid Valve & 120V Coil Compressor Service Valve Suction Valve, Sporlan CRO-4-0/75 Crankcase Pressure Reg.
parts information QC2-3 ContRol Box 3 1 4 2 8 9 Item 1 2 3 4 5 6 7 8 9 Part BK-29919 FU-29934 CC-36419 BA-29927 CB-35746 PE-36160 PN-29932 CB-36571 CC-36418 7 6 Description Block, 20 Amp Fuse Holder Fuse, 20 amp, Time Delay, #SLC020 480V Class G Control Board Power Supply, 115V to 12VDC Connector, USB, Panel Mount Panel Overlay Control Panel USB Communication Cable w/ plug User Interface Board and Firmware QUICKCHILLER • MN-36580 (REV. 0) • INSTALLATION/OPERATION/SERVICE MANUAL • 39. 5 Qty.
parts information QC-20 Box view 1 2 3 4 11 5 12 14 9 10 8 13 7 6 Item 1 2 3 4 Part PR-35771 RE-29905 PR-36201 DR-29957 contact factory 5 6 7 8 HD-29958 SC-29837 HG-29836 HG-29834 Description Probe Receptacle Assembly Coil Assembly Probe, Product Door Assembly with Handle, Hinged Left Door Assembly with Handle, Hinged Right Door Handle, Recessed Bolt, Black Set Screw Hinge, Strap w/ Collar 41mm, L-shaped Hinge, Self-Closing Qty.
parts information QC-20 coil view 1 2 3 15 4 14 5 13 6 12 11 10 8 9 Item 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Part TE-35100 RE-29905 PR-35771 PR-36201 SN-33541 SN-34663 PN-29943 CD-29860 VA-29900 LT-29940 BU-29937 FA-29945 SC-29935 SC-29936 HG-29938 7 Description Tee, Copper, 1/2 x 1/2 x 1/4 Coil, QC2-20 QuickChiller Probe Receptacle Assembly Probe, Product Sensor, Air Coil Sensor/, Defrost/Sensor Drip Pan Wire, 11" (279mm) Loop Drain Heater Expansion Valve Latch, Plate for Fan Door Bushing, N
parts information QC-20 Compressor view 13 11 12 9 10 9 7 8 6 5 4 3 Item 1 2 3 4 5 6 7 8 9 10 11 12 13 14* 15* Part PE-29968 BT-29950 PN-29949 BT-29967 RE-29948 FI-29954 ** BT-29951 RE-29966 EL-29828 FU-29965 CU-29964 VA-29893 MO-29955 FA-29956 *not shown 2 1 Description Compressor Louver Bracket, Front Compressor Hold Down Housing Louver Mounting Bracket Condensing Unit, 3/4 HP LT R404A 120V Filter Dryer Compressor Bracket, Back Compressor Hold Down Condensate Evaporator Pan, includes Hold Do
parts information QC-20 Control PaneL 1 2 10 3 9 8 4 7 6 5 Item 1 2 3 4 5 6 7 8 9 10 11* Part CC-36418 SC-29991 PE-36130 CB-35746 PN-29962 CB-36571 FU-29934 BK-29919 BA-29927 CC-36419 5017512 Description User Interface Board and Firmware Screw, 6-32x1/2 T/H/P 18-8 SS Philllips Truss Panel Overlay Connector, USB, Panel Mount Control Panel USB Communication Cable Fuse, 20 amp Fuse Holder Block Board, Power Supply Control Board Beeper Assembly *not shown QUICKCHILLER • MN-36580 (REV.
parts information QC2-40 compressor 4 3 2 1 5 2 6 7 8 9 Item 1 2 3 4 5 6 7 8 9 Part VA-29898 SE-29897 VA-29900 FI-29899 ** ** EL-29828 WI-35102 PN-29903 RE-29896 Description Valve, Liquid Line Solenoid Solenoid Valve & Coil, Danfoss, 120V Valve, Sporlan Crankcase Pressure Regulator Filter Drier Fan Guard Compressor Element Condensate Pan, 115V 200W Evap. - 120V Element Condensate Pan, 115V 200W Evap. - 220V Evaporator Pan, without Element Condensing Unit, 1.
QC2-40 compressor Housing parts information 4 1 3 Item Part 1 PE-36749 2 BT-29950 3 5014889 LG-29904 SC-29824 SC-29824 4 PN-29903 5* CD-35103 2 Description Compressor Louver Hold Down Clip Leg Assembly (Set of 4) Leg, 6" Bolt, 1/4" .20" x 5" Shoulder Leg Bolt, 1/4-20 x 3.5" Shoulder Bolt Hex Head Evaporator Pan, without Element Cord and Plug, 125/250V 20 Amp 14-20P, 9' Long *not shown QUICKCHILLER • MN-36580 (REV. 0) • INSTALLATION/OPERATION/SERVICE MANUAL • 45. Qty.
parts information Q C 2 - 4 0 C OIL 9 10 11 8 1 7 2 6 5 4 3 Item 1 2 3 4 5 6 7 8 9 10 11 Part SN-33541 ** ** SN-34663 VA-29906 ** ** RE-29905 ** PR-35486 PR-35770 Description Air Sensor Air Sensor Mounting Bracket Housing, Refrigeration Enclosure Coil Sensor/, Defrost/Sensor Valve, Expansion Drain Pan, Evaporator Clip, Left, Coil Evaporator Coil Clip, Right, Coil Probe Receptical Probe **not available from factory QUICKCHILLER • MN-36580 (REV. 0) • INSTALLATION/OPERATION/SERVICE MANUAL • 46.
parts information Q C 2 - 4 0 D OOR 1 5 4 3 2 Item Part 1 DR-36748 contact factory 2 3 4 5 HD-29958 HG-36650 HL-29840 GS-29914 Description Door Assembly, Left-Hand Door Assembly, Right-Hand Handle, Door Hinge Food Probe Holder Gasket, Door QUICKCHILLER • MN-36580 (REV. 0) • INSTALLATION/OPERATION/SERVICE MANUAL • 47. Qty.
parts information QC2-40 pan supports 1 Item Part 1 SR-36881 Description Rack, Pan Support Qty. 18 QUICKCHILLER • MN-36580 (REV. 0) • INSTALLATION/OPERATION/SERVICE MANUAL • 48.
parts information QC2-40 Control Panel 9 10 8 1 2 3 4 7 5 6 Item 1 2 3 4 5 6 Part BA-29927 CB-36571 CC-36419 CU-29964 SC-29991 CC-29930 7 8 9 10 11* CB-35746 PE-36160 CC-36418 SW-36882 5017512 contact factory Description Power Supply Board, 115V-12VDC, 40W, 60C op Temp USB Communication Cable w/ plug Control Panel Capacitor, 14MFD, 440VAC Screw, 6-32 x 1/2 T/H/P 180-8 SS 08BC Phillips Truss SS Control Panel Assembly, Left-Hand Control Panel Assembly, Right-Hand Connector, USB Panel Mount Pane
parts information QC2-100 compressor 8 7 6 5 1 2 13 3 4 2 12 11 9 10 Item 1 2 3 4 5 6 7 8 9 10 11 12 13 Part TE-29986 SE-29857 TE-35153 VA-29898 TE-35154 EL-35152 FI-29987 VA-29988 ** RE-29983 RE-35172 ** ** ** Description Tee, Copper, 3/8 x 3/8 x 3/8" ID Solenoid Valve & Coil, Danfoss, 120V Tee, Copper, 1/2 x 1/2 x 3/8" ID Valve, Liquid Line Solenoid Tee, Copper, 1-1/8 x 1-1/8 x 5/8" OD Elbow, Copper 1/4" Street Filter Drier CPR Valve Compressor Condensing Unit, 3HP 208/230V 1 Phase Condensing
parts information Q C 2 - 1 0 0 c o IL 4 1 2 3 Item 1 2 3 4 5* 6* Part RE-29905 VA-29906 TE-35153 TE-29985 FA-29945 SN-34663 Description Coil Assembly, 19x20 Valve, Expansion Tee, Copper, 1/2 x 1/2 x 3/8" ID Tee, Copper, 1/2" x 1/2" x 1/4" ID Evaporator Fan Motor Coil Sensor, Defrost/Sensor *not shown QUICKCHILLER • MN-36580 (REV. 0) • INSTALLATION/OPERATION/SERVICE MANUAL • 51. Qty.
parts information Q C 2 - 1 0 0 D OOR 7 1 6 5 2 4 3 Item Part 1 DR-29990 contact factory 2 3 4 5 6 7 HD-26967 HD-26966 HG-36650 GS-29994 GS-29993 HL-29840 SC-29991 Description Door Assembly, Left-Hand Door Assembly, Right-Hand Handle, Door, LH Handle, Door, RH Hinge, Adjustable Gasket, Compression Gasket, Door Food Probe Holder Bolt, 8-32 X 1/2, Philliips Truss QUICKCHILLER • MN-36580 (REV. 0) • INSTALLATION/OPERATION/SERVICE MANUAL • 52. Qty.
Q C 2 - 1 0 0 INTERIOR ( l e f t - h a n d parts information door shown) 1 11 12 13 14 15 2 10 3 9 8 6 7 Item Part 1 RE-29983 RE-35172 2 PN-29842 3 PN-29999 contact factory 4 DR-29990 contact factory 5 6 7 8 HG-36650 GS-29994 contact factory 5016746 LG-29904 SC-29824 Description Condensing Unit, 3HP 208/230V 1 Phase Condensing Unit, 3HP 208/230V 3 Phase Louver Panel Panel, Control Panel Assembly, Left-Hand Panel, Control Panel Assembly, Right-Hand Door Assembly, Left-Hand Door Assembly, Righ
parts information QC2-100 Control Panel (left-hand shown) 11 10 1 9 8 2 7 6 3 4 5 Item 1 2 3 4 Part PE-36160 CB-35746 CB-35769 PN-29999 5 LT-26968 LT-26969 CU-29964 CC-36419 PN-35934 BA-29927 SC-29991 CC-36418 5017512 contact factory 6 7 8 9 10 11 12* Description Panel Overlay Connector, USB, Panel Mount USB Communication Cable Control Panel, Left-Hand Control Panel, Right-Hand Door Latch, Left-Hand Door Latch, Right-Hand Capacitor, 14MFD, 440VAC Control Board Bracket, Fan Mounting Power Supp
TRANSPORTATION DAMAGE and CLAIMS 1. 2. 3. 4. 5. 6. 7. 8. All Alto-Shaam equipment is sold F.O.B. shipping point, and when accepted by the carrier, such shipments become the property of the consignee. Should damage occur in shipment, it is a matter between the carrier and the consignee. In such cases, the carrier is assumed to be responsible for the safe delivery of the merchandise, unless negligence can be established on the part of the shipper.