Operating instructions
PG. 6 #8401 QC-100 INSTALLATION & MAINTENANCE MANUAL
2.1.1 Place the branch circuit breaker (main
panel) in the ON position. Then place the
Quickchiller circuit breaker in the ON
position.
2.1.2 The Main Menu screen must appear on
the Control display (see figure 2.1.3). If
the Main Menu screen appears, skip
Sections 2.1.3 thru 2.1.5 and proceed with
SET-UP per Section 2.2. If the Main Menu
screen does not appear, proceed with
Section 2.1.3.
2.1.3 The control display will show "SYSTEM
INITIALIZED" and an audible alarm will
sound for 30 to 60 seconds. Leave the
unit alone for two (2) minutes.
2.1.4 Turn the Quickchiller circuit breaker OFF.
Leave the unit OFF for 30 seconds.
2.1.5 Turn the Quickchiller circuit breaker ON
again. The Main Menu screen on the
display should now appear.
2.2 SET-UP
2.2.1 Make certain the main menu appears on
the control display (LCD) when power is
supplied to the unit.
2.2.2 Access the Password screen: Press and
hold the "0" button on the keyboard for a
period of 5 seconds. When the Password
Entry screen is in view, enter the
password number on the numerical
keyboard.
Following password entry, press "D" on
the keyboard to access the User Setting
Menu screen. If the wrong password
number is entered in error, "Access
Denied" will appear in the display. If it
remains in the display longer than 60
seconds, the locked control panel cover
must be opened and the yellow reset
button pressed ONCE. Relock the control
panel and enter the correct password to
gain access to the User Setting Menu
screen.
2.2.3 Select option "B" and set the correct time
and date.
Following entry, press "C," immediately
followed by "D" to return to the Main
Menu screen. (
FOR ADDITIONAL
INFORMATION SEE BOOKLET NO
. 265,
Quickchiller Operating Procedure Guide,
SECTION 7.0 USER SET-UP.)
2.2.4 Press and hold the "1" button on the
keyboard for a period of five (5) seconds.
The Software Version screen will appear.
Quickchiller Model QC-100 must appear.
If Model QC-100 appears, proceed with
Section 2.3. If Model QC-100 does not
appear, proceed with Sections 2.2.5
through 2.2.7.
2.2.5 Press and hold the "0" button on the
keyboard again until Password Entry
screen appears. Enter password number
on the numerical keyboard.
Press "D" button to access Set-up Menu
Screen.
2.2.6 Select option "C" and set correct Chiller
Model to "QC-100" using the "C" button.
Following entry, press "D", and press "D"
again to return to Main Menu screen.
2.2.7 The QC-100 is now ready for operation.
2.0 — Control Set-Up and Operation
Password
5588744
Password
16021892
NOTE: BACK-UP BATTERY POWER
The Quickchiller control back-up battery is
fully charged prior to Quickchiller shipment
and will maintain control memory for
approximately fourteen (14) days.
NOTE:T
WENTY-FOUR (24) HOUR TIME OR
MILITARY TIME IS REQUIRED
.
1:00 PM = 1300
MILITARY TIME
FOR A COMPLETE AND COMPREHENSIVE GUIDE
TO THE OPERATION OF THE QUICKCHILLER SEE
BOOKLET NO. 265,
QuickchillerOperating Procedure Guide
2.1 START-UP PROCEDURES