Operating instructions

PG. 12 #8401 QC-100 INSTALLATION & MAINTENANCE MANUAL
3.1 INTRODUCTION
To insure trouble free operation and the highest level of sanitation control, periodic cleaning and
maintenance is required. The maintenance system should be aimed at maximizing the efficient
utilization of maintenance personnel, minimizing down time, and providing the orderly acquisition
of spare parts for support. If already established at the location site, perform scheduled
maintenance in accordance with the standards in the Maintenance Index Plan.
The Alto-Shaam® Quickchiller should be cleaned and sanitized a minimum of once a week.
Good equipment that is kept clean works better and lasts longer. Protect your investment.
Always follow appropriate state or local health (hygiene) regulations regarding all applicable cleaning and
sanitation requirements for equipment.
3.2 INTERIOR CLEANING
Disconnect unit from power source. Remove
the slide-in pan rack and rack-track and leave
the door open to warm the interior of the
cabinet.
1. Remove any loose food debris from cabinet
with a cleaning cloth or small hand broom.
2. Wipe down the interior of the cabinet
with a damp cloth and any good
alkaline or alkaline chlorinated based
commercial detergent or grease solvent
at the recommended strength. Use a
plastic scouring pad for difficult areas.
Avoid the use of abrasive cleaning
compounds, chloride based cleaners, or
cleaners containing quaternary salts.
Be sure to clean the ceiling, floor, walls and fan
panel. Clean the vinyl gaskets and the interior
door panel. Make certain to clean under the
gaskets to remove any mildew accumulation or
food residue.
3. Rinse everything with clean water and cloth
to remove all residue.
Allow cabinet
interior to air dry
with the door open.
3.3 EXTERIOR CLEANING
Disconnect unit from power source.
1. Wipe all exterior surfaces including the control
panel, door frame, latches, and hinges with a
damp cloth containing a mild, non-abrasive
detergent solution without chlorine. Rinse with
cloth and warm water Allow to air dry.
2. To help maintain the protective film coating on
polished stainless steel, clean the exterior with
a cleaner recommended for stainless steel
surfaces. Spray the cleaning agent on a cloth
and wipe with the grain of the stainless steel.
3. Avoid an accumulation of oil based polish or
cleaner collecting along the edges of the
keyboard overlay on the control box. Oil build-
up around the control overlay could eventually
loosen the panel.
3.0 — Cleaning & Maintenance
DEACTIVATE THE SYSTEM BY
DISCONNECTING THE POWER SUPPLY
BEFORE PERFORMING ANY CLEANING OR
MAINTENANCE WHICH INVOLVES PLACING
HANDS NEAR MOVING PARTS.
WARNING
!
!
CAUTION
DO NOT USE SPRAY OR PRESSURE HOSE
CLEANING TECHNIQUES ON THE
EXTERIOR OR INTERIOR OF THE
CABINET. WATER DAMAGE CAN