Q U I C K C H I L L E R   •   I NS T A L LA T I O N/ O P E RA T I O N/ S E R VI C E   M AN U A L   •   28.
TITLETROUBLESHOOTING
CONTROL ERROR DISPLAYS
control display action required
Real Time Clock Bad
E-60: REAL TIME CLOCK DEFAULTS LOADED, 
VERIFY CORRECT TIME, POWER CYCLE UNIT TO 
CLEAR THIS MESSAGE.
This is likely caused by the unit having been unplugged for an extended 
amount of time. The data stored in the Real-Time Clock has been reset to 
the factory default values. Contact service if problem persists.
Real Time Clock Not Detected
E-61: REAL TIME CLOCK NOT DETECTED.  
POWER CYCLE UNIT AND CALL FOR  
SERVICE IF THE PROBLEM PERSISTS. 
Real Time Clock not detected. Contact service if problem persists. 
Button Stuck
E-90: BUTTON STUCK. CHECK ALL BUTTONS AND 
ERROR WILL CLEAR WHEN THE PROBLEM HAS 
BEEN RESOLVED
This error message indicates that a button is stuck. Check all buttons.  
Error will clear when the problem has been solved. Contact service is 
problem persists. 
Using Default Function Values
E-80 - EEPROM ERROR 
USING DEFAULT FUNCTION VALUES
This error message indicates the control memory is not correctly reading 
user-set values. The Quickchiller will remain operational but the user 
defined settings will be reloaded to the default values. The control will 
revert to factory default settings and will require operator modification 
each time the unit is used. Call Service. Acknowledge error by pressing 
the power button.
Probe Open/Shorted
PROBE N* OPEN -OR- PROBE N* SHORTED
CALL FOR SERVICE
This error message indicates a problem with the probe identified within the 
display. The Quickchiller will operate normally in the Time mode but will 
not operate in the Probe mode. Call service.
*N signifies probe number that is shorted: 1= top, 2= middle, 3= bottom
Cavity Open Shorted
CAVITY SENSOR OPEN OR SHORTED.
CALL FOR SERVICE
This error message indicates a problem with the interior cavity sensor. The 
Quickchiller will not operate in any operational mode. Call service.
Coil Open Shorted
COIL N* OPEN OR COIL N* SHORTED
CALL FOR SERVICE
This error message indicates a problem with the display identified coil 
sensor. The Quickchiller will remain operational but will extend the 
defrost cycle to the full period of 20 minutes. Call service.
*N signifies coil number that is shorted.
Bad Calibration
E-81: BAD CALIBRATION. PLEASE CALL SERVICE 
AD1-0=(PASS) (FAIL) AD1-1=(PASS)(FAIL) 
AD2-0=(PASS)(FAIL) AD2-1=(PASS)(FAIL) 
AD3-0=(PASS)(FAIL) AD3-1=(PASS)(FAIL)
Calibration bad. Call service.
Note: Display will signify PASS where calibration is good, or FAIL 
where calibration is bad.
Requires Calibration
E-82: REQUIRES CALIBRATION.  
PLEASE CALL SERVICE 
Requires Calibration. Call service.
Power Failure
POWER WAS OFF FOR HH:MM 
PRESS PROGRAM TO ACKNOWLEDGE
Power has been off. Press Program to acknowledge.
NOTE: If such an event has occurred, it is strongly recommended 
that you ensure the food is safe for consumption according to 
local health regulations.