Operating instructions

Ga s Fr yer Op er a ti on & Ca re M an ua l 46
D E L U X E C O N T R O L O P E R A T I O N
P R O G R A M M I N G T H E C O N T R O L
BsktLift
The Basket Lift program provides the operator with the ability to enable or disable the
automatic basket lift function. In the ON position, the baskets will lift automatically as
programmed in the selected product procedure. In the OFF position, both baskets will
remain in the raised position until manually dropped by the operator. This function is set
in the ON position as received from the factory. I
T IS STRONGLY RECOMMENDED
THAT THE BSKTLIFT REMAIN AT THIS SETTING. If it is ever necessary to
transition from the disabled OFF position to the enabled ON position, the control
display will indicate POWERDOWN requiring the operator to perform a control
shutdown in order to synchronize the baskets with the revised state of the control.
Turn the Master Power Switch (located behind the front access door) to the OFF position.
Press the Up or Down arrow keys to scroll until BsktLift appears in the display.
Press the Right arrow key to enter the program. Display stops flashing. The previous
setting will appear in the display. Press the Up or Down arrow keys to change the
setting. When the correct setting appears, press the Right arrow key to confirm.
Display flashes. Press the Down arrow key to advance the control to the next
setting option.
LiftSync
AVAIL ABLE ON D UAL-CONTROL FRYERS ONLY. The LiftSync program provides the ability
to raise both basket lifts simultaneously by selecting the ON position. The factory
preset is in the OFF position for independent operation.
Press the Up or Down arrow keys to scroll until LiftSync appears in the display.
Press the Right arrow key to enter the program. Display stops flashing. Press the Up
and Down arrow keys to toggle between ON and OFF. When the selection has
been made, press the Right arrow key to to confirm the selection. Display flashes. Press
the Down arrow key to advance the control to the next programming function.
Temp F/C
The temperature display can be shown in degrees Fahrenheit or Celsius.
Press the Up or Down arrow keys to scroll until Temp F/C appears in the display.
Press the Rightarrow key to enter the program. Display stops flashing. The current
setting will appear in the display. Press the Up or Down arrow keys to toggle
between F and C. Press the Right arrow key to accept the desired selection.
Display flashes. Press the Down arrow key to advance the control to the next
programming function.
F
Temp F/C
ON
LiftSync
O N
BsktLift
To exit the control programming mode at any time, press and hold the LEFTarrow key.