An electrical wiring diagram is located in the front
access door of the fryer. The fryer must be installed by a
qualiedelectrician.Thisappliancemustbebranchcircuit
protected with proper ampacities, in accordance with
the wiring diagram located in the fryer. The fryer must
be properly grounded in accordance with the National
Electrical Code and applicable local codes. A means to
disconnecttheunitmustbeincorporatedintothexed
wiring in accordance with wiring codes.
Wiresizeforthemainincomingpowertotheunitmust
matchtheminimumsizelistedinthespecications
applicabletothespecicfryer.Forsupplyconnections,
locate the wire size posted on the label located on the
electricalcontrolboxcover,behindtheservicepanelor
elsewhere listed in this manual.
Before operating the fryer, check all cable connections
in the electrical connection area for tightness since
connections can loosen during transport.
230V:
To prevent an electrical shock hazard between the
appliance and other appliances or metal parts in close
vicinity, an equalization-bonding stud is provided. An
equalization bonding lead must be connected to this
stud and the other appliances / metal parts to provide
sufcientprotectionagainstpotentialdifference.The
terminal is marked with the following symbol.
DANGER
To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code ANSI/
NFPA No. 70. In Canada, all electrical
connections are to be made in
accordance with CSA C22.1, Canadian
Electrical Code Part 1 or local codes.
DANGER
ENSURE POWER SOURCE
MATCHES VOLTAGE STAMPED
ON APPLIANCE NAMEPLATE.
ELECTRICAL REQUIREMENTS
ELECTRICAL • ASF-75G with deluxe control
voltage phase cycle/hz amps kw
120 (agcy) 1 60 7.2 0.86
230 (agcy) 1 50/60 4.0 0.92
n e m a 5-15P
15A-125V Plug
ELECTRICAL • ASF-60G with deluxe control
voltage phase cycle/hz amps kw
120 (agcy) 1 60 1.2 0.15
230 1 50/60 1.0 0.23
n e m a 5-15P
15a-125V Plug
c e e 7 / 7
220-230V Plug
c e e 7 / 7
220-230V Plug
INSTALLATION
Gas Fryer Operation & Care Manual • 11
Hard wired models:
Hard wired models must be equipped with a
countrycertifiedexternalallpoledisconnection
switch with sufficient contact separation.
If a power cord is used for the connection of the
productanoilresistantcordlikeH05RNorH07RN
or equivalent must be used.