ERROR CODES
Error
Code
Error Call Out in Display Description of Error Possible Cause
E108
Cooling Fan Failure If the temperature on the
control board (relay board) is
greater than 140ºF (60ºC) and
less than 176ºF (80ºC). (See
error code E02)
— Cooling fan damaged.
Cooling fan blocked or blades have been kept
from rotating.
— Incoming air temperature exceeds 100°F (38°C).
— Air inlet has become blocked.
E109
High Limit Switch The High Limit Switch input
to the CB (N7) is “open”
— Unit has experienced an over heat condition.
— Convection element contactors stuck closed.
— Failed Y1 solenoid.
Obstruction between Y1 solenoid and injection
pipe.
— Improperly connected drain.
— Condensate pan clean out not closed.
Improperly wired high limit switch at the switch
or at the CB.
— Defective high limit switch.
E200
The SD card has been
detected to be larger than
2GB in size.
The SD card inserted is larger
than 2GB in size.
— SD card is larger than 2GB in size. Contact
service to order replacement SD card.
see motor control error chart on next page