Specifications

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 54.
COMBITHERM® POST INSTALLATION CHECKLIST


CUSTOMER INFORMATION:
Street Address:
Date of Installation:
Customer Name: City:
State: Zip:
CLEARANCES:
Write the actual measured distances in the boxes provided:
Left:
Back:
0" (0mm) required - 18" (457mm) recommended for
service access
4" (102mm) required
Right: Top:
0" (0mm) from non-combustible surfaces;
2" (51mm) from combustible surfaces
20" (508mm) required
Are all clearance requirements met?
 
WATER SUPPLY AND DRAINS:
Verify hook up of two (2) separate  water lines with a 3/4" (19mm) Water connection supply line. Verify Inlet water
pressure is at a minimum of 30 PSI (2.1 bar). Maximum water pressure is not to exceed 90 PSI (6.3 bar). 
Alto-Shaam has listed water quality requirements in the installation manual for this equipment. It is the responsibility of the
end user to have the water being connected to this appliance tested to ensure it meets with these standards. Failure to meet with
these standards can void the warranty of the equipment if water quality is found to be the reason of the failure.
Has a filtration system been installed?
 
Type?
Has a complete water Analysis been complete?
 
Static water pressure:
ELECTRICAL CONNECTIONS:
Rated Voltage: Rated Phase:
Breaker Size:
Actual Voltage:
L1-N L2-N L3-N L1-L2 L1-L3 L2-L3
Gas Connections
Rated Gas Supply Nat LP Actual Gas Supplied Nat LP
 Improper drain connections can result in equipment failure. Alto-Shaam drain requirements are located in the installation
manual for this equipment. Failure to meet these standards can void warranty if the failure is found to have been caused by an
improperly connected drain. It is the responsibility of the installer to ensure the manufactures requirements are met in the plumbing of
the drain system.
DRAIN:
Type of material used for drain?
Is a 2" (51mm) air gap installed?
 
Is the air gap within 12" (305mm) of the CombiOven?
 
Is the drain piped with a positive descending slope?
 
Use the diagrams provided to crate a simple diagram showing how the drain plumbing is ran. Include measurements showing
the distance to the floor drain, location of the air gap, and venting of the drain. Drain plumbing requirements can be found in the
installation manual.
NOTES: