Specifications
COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 44.
INSTALLATION
GAS SUPPLY & INSTALLATION
LEAK TESTING
GAS EXHAUST
The oven is not designed for direct connection to a
chimney vent system or for direct connection to a
horizontal exhaust system.
The oven must be installed under a ventilation
hood listed to ANSI/UL 705 (latest edition), and the
installation must be completed in accordance with
the ANSI/NFPA 96-1987, Standard for Ventilation
Control and Fire Protection of Commercial Cooking
Operations.
Oven operators should be instructed with regard
to the hazards of placing any material on top of the
oven that would obstruct
the flow of flue products
out the opening of the flue
diverter. Operators should
also be instructed with
regard to the hazards of
hot flue gases and that any
material or items placed on
top of, or in front of the flue
defector could be damaged
or cause a fire hazard.
DANGER
NEVER USE AN OPEN
FLAME TO LEAK TEST.
DANGER
BEFORE STARTING THE
APPLIANCE, MAKE CERTAIN
YOU DO NOT DETECT THE
ODOR OF GAS.
IF THE ODOR OF GAS IS DETECTED:
• DO NOT attempt to light any appliance.
• DO NOT touch any electrical switches.
• Extinguish any open fl ame.
• Use a telephone OUTSIDE THE
PROPERTY & IMMEDIATELY
contact your gas supplier.
• If unable to contact your gas supplier,
contact the fi re department.