Specifications
COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 36.
INSTALLATION
ELECTRICAL FOR GAS MODELS
1. An electrical wiring diagram is located behind
the control panel on the left side of the oven.
This appliance must be branch circuit protected
with proper ampacities, in accordance with the
wiring diagram.
2. do not connect to a g.f.I. outlet. Random
and/or nuisance breaker trips could occur. Consult
with the NEC codes for specic load values.
3. Wire size for the main incoming power to the
unit must match the minimum size listed in the
specifications applicable to the specific oven
model. For supply connections, locate the wire
size posted on the label located on the electrical
control box cover, behind the service panel.
4. Before operating the oven, check all cable
connections in the electrical connection area
for tightness since connections can loosen
during transport.
NOTE:
DANGER
To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code ANSI/
NFPA No. 70. In Canada, all electrical
connections are to be made in
accordance with CSA C22.1, Canadian
Electrical Code Part 1 or local codes.
DANGER
ENSURE POWER SOURCE
MATCHES VOLTAGE IDENTIFIED
ON APPLIANCE RATING TAG.
DANGER
ELECTRICAL GROUNDING
INSTRUCTIONS:
This appliance is equipped with a
three-pronged (grounding) plug for
your protection against shock hazard
and should be plugged directly into
a properly grounded three-prong
receptacle. Do not cut or remove the
grounding prong from this plug.
DANGER
AVERTISSEMENT: Directives
pour la prise de courant électrique Cet
appareil est muni d'une fi che à trios
branches (prise de Courant) afi n de
vous proéger des chocs et doit être
branché Directemet dans un receptacle
adequate de prise do courant À trios
branches. II ne faut pas couper ou
enlever une banche De cette fi che.
To prevent an electrical
shock hazard between the appliance and other
appliances or metal parts in close vicinity, an
equalization-bonding stud is provided. An
equalization bonding lead must be connected to
this stud and the other appliances / metal parts
to provide sufficient protection against potential
difference. The terminal is marked
with the following symbol.
DANGER
DISCONNECT UNIT FROM
POWER SOURCE BEFORE
CLEANING OR SERVICING.
380-415V: