Specifications

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 33.
INSTALLATION
SITE INSTALLATION
NOTE: Note dimensions required
for doorways and aisles
for access of the oven and
pallet to the installation site.
Transport the oven in an
upright and level position
only. Do not tilt the oven.
components
protrude below
oven
NOTE: To avoid equipment damage,
observe attention label on
oven for area to avoid with
lifting fork.
CAUTION
THE APPLIANCE MUST REMAIN ON
THE PALLET WHILE BEING MOVED
TO THE INSTALLATION SITE BY FORK
LIFT OR PALLET LIFT TRUCK.
INSTALLATION
To insure proper operation, the installation of this oven
must be completed by qualified technicians in accordance
with the instructions provided in this manual. Failure to
follow the instructions provided may result in damage to
the oven, building, or cause personal injury to personnel.
depth of
forks is
critical
for units
equipped
with grease
collection
to avoid
damaging
the pump
LIFTING INSTRUCTIONS
Remove banding before lifting. Lift the unit from the
front only, never from the side.
Adjust the forks so that they do not damage any of the
components under the unit. 
 Lift the unit just
high enough to remove the wooden pallet. Lower the
unit as close to the floor as possible and no more than 2"
(50mm) above the floor. Secure hoses and dangling cords
to avoid tangling or damage. When moving the unit,
drive slowly, keep it low to the ground, and use
extreme caution.
®