Specifications
COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 24.
GAS REQUIREMENTS
(GAS TYPE MUST BE SPECIFIED ON ORDER)
HOOK-UP: 3/4" NPT Alternate burner orifi ce is required for installation sites at elevations of 2,000 feet (610m) above sea level
RATED THERMAL LOAD CONNECTED PRESSURE
NORTH AMERICA INTERNATIONAL NORTH AMERICA INTERNATIONAL
Natural Gas/Propane G20, G25, G31 Natural Gas Propane
G20 20mbar
Gross Heating Value (HHV) Net Heating Value (LHV) Minimum: 5.5" W.C. Minimum: 9" W.C.
G25 20mbar
121,000 Btu / hr 32.0 kW
Maximum: 14" W.C. Maximum: 14" W.C.
G31 30mbar
ELECTRICAL
(NO CORD, NO PLUG UNLESS SPECIFIED, DEDICATED CIRCUIT REQUIRED) DO NOT CONNECT TO A G.F.I. OUTLET
MODEL VOLTAGE PH HZ AWG CONNECTION AMPS kW
NORTH AMERICA
120 1 60 14
NEMA 5-15P,
15A, 125V Plug
7.0 .84
other voltages available upon request
INTERNATIONAL
208 – 240 3 50/60 14 L1, L2, L3, G 4.8 – 4.2 1.0
380 – 415 3 50 14 L1, L2, L3, N, G 4.6 – 4.2 1.0
CTC10-20G
WEIGHT SHIP DIMENSIONS PAN CAPACITY
NET 760 lbs est 344 kg
(L x W x H)
56" x 48" x 65"*
FULL–SIZE: 20" x 12" x 2-1/2" Twenty (20)
PRODUCT MAXIMUM: 240 lb (109 kg)
SHIP 800 lbs* 362 kg* (1422 x 1219 x 1651mm)*
GN 1/1: 530 x 325 x 65mm Twenty (20)
VOLUME MAXIMUM: 150 quarts (190 liters)
*
DOMESTIC
GROUND
SHIPPING
INFORMATION
.
CONTACT
FACTORY
FOR
EXPORT
WEIGHT
AND
DIMENSIONS
.
GN 2/1: 650 x 530 x 65mm Ten (10)
*ADDITIONAL WIRE SHELVES REQUIRED FOR
MAXIMUM CAPACITY
*FULL–SIZE SHEET: 18" x 26" x 1" Ten (10)
*ON WIRE
SHELVES ONLY
WATER REQUIREMENTS WATER QUALITY STANDARDS
TWO (2) COLD WATER INLETS - DRINKING QUALITY
ONE (1) TREATED WATER INLET: 3/4" NPT*
ONE (1) UNTREATED WATER INLET: 3/4" NPT*
LINE PRESSURE: 30 to 90 psi 2.1 to 6.3 bar
WATER DRAIN:
1-1/2"
CONNECTION WITH A
2"
MINIMUM AIR GAP INSTALLED AS CLOSE TO THE OVEN AS
POSSIBLE. MATERIALS MUST WITHSTAND TEMPERATURES UP TO
200°F (93°C).
It is the sole responsibility of the owner/operator/purchaser of this equipment
to verify that the incoming water supply is comprehensively tested and if
required, a means of “water treatment” provided that would meet compliance
requirements with the published water quality standards published below.
Non-compliance with these minimum standards will potentially damage this
equipment and/or components and VOID the original equipment manufacturer’s
warranty. Alto-Shaam recommends using OptiPure
®
[www.optipurewater.com]
products to properly treat your water.
CLEARANCE REQUIREMENTS
Contaminant
Free Chlorine
Hardness
Chloride
pH
Silica
Total Dissolved Solids (tds)
Inlet Water Requirements
Less than 0.1 ppm (mg/L)
30-70 ppm
Less than 30 ppm (mg/L)
7.0 to 8.5
Less than 12 ppm (mg/L)
50-125 ppm
LEFT: 0" (0mm) 18" (457mm)
FOR SERVICE ACCESS
RIGHT: 0" (0mm)
NON-COMBUSTIBLE SURFACES
2" (51mm)
COMBUSTIBLE SURFACES
TOP: 20" (508mm)
FOR AIR MOVEMENT
BACK: 4" (102mm) BOTTOM: 5-1/8" (130mm)
FOR LEGS, AIR INTAKE
INSTALLATION REQUIREMENTS
• Oven must be installed level. • Hood installation is required.
• Water supply shut-off valve and back-flow preventer when required by local code.
* Can manifold off of one
3/4" line.
DIMENSIONS: H x W x D
EXTERIOR:
45-11/16" x 43-3/4" x 46-3/16" (1160mm x 1111mm x 1173mm)
EXTERIOR WITH RECESSED DOOR:
45-11/16" x 47-3/4" x 46-3/16" (1160mm x 1213mm x 1173mm)
INTERIOR:
31-1/2" x 24-1/4" x 32-3/4" (800mm x 616mm x 832mm)
NOTES:
ALL DIMS DISPLAYED AS H x W x D
INTERIOR DIMENSIONS: 800mm x 616mm x 832mm
EXTERIOR DIMENSIONS: 1173mm x 1111mm x 1115mm
10.18esg2
805605
43-3/4" (1111mm)
46-3/16" (1173mm)
34-1/4" (870mm)
4-5/8" (117mm)
45-11/16" (1160mm)
30-13/16" (783mm)
21-1/2" (545mm)
6.10 GAS OVER 10.18 GAS: 2059mm x 1111mm x 1115mm
10.18 GAS ON 28" STAND: 2014mm x 1111mm x 1115mm
4-1/2" (114mm)
4-1/4" (108mm)
6-11/16" (168mm)
C - at bottom
of oven
A, B, D, E
47-7/16" (1205mm)
73-5/16" (1863mm)
30-1/2" (775mm)
21-1/2" (545mm)
9-1/16" (230mm)
5-7/8" (149mm)
6-15/16" (176mm)
6-13/16" (171mm)
4-5/16" (109mm)
3-5/16" (84mm)
10.20 GAS
9-1/16" (230mm)
5-7/8" (149mm)
30-1/2" (775mm)
1-11/16" (42mm)7-5/8" (194mm)
A
A
B
B
C
D
D
E
E
A= UNTREATED WATER
B= TREATED WATER
C= ELECTRICAL
D= GAS
E= WATER DRAIN
CTC10-20G
Ga s boilE r-frEE