Specifications
COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 14.
ELECTRICAL
(NO CORD, NO PLUG, DEDICATED CIRCUIT REQUIRED) DO NOT CONNECT TO A G.F.I. OUTLET
MODEL VOLTAGE PH HZ AMPS kW AWG CONNECTION
CTC10-10E
208 – 240 3 50/60 47 – 52 15.7 – 20.4 6 L1, L2, L3, G
380 – 415 3 50 31 – 33 17.4 – 20.4 8 L1, L2, L3, N, G
440 – 480 3* 50/60 28 – 30 17.4 – 20.4 8 L1, L2, L3, G
*ELECTRICAL SERVICE CHARGE APPLIES
WEIGHT SHIP DIMENSIONS PAN CAPACITY
NET 625 lbs est 283 kg
(L x W x H)
56" x 45" x 65"*
FULL–SIZE: 20" x 12" x 2-1/2" Ten (10)
PRODUCT MAXIMUM: 120 lb (54 kg)
SHIP 675 lbs* 306 kg* (1422 x 1143 x 1651mm)*
GN 1/1: 530 x 325 x 65mm Ten (10)
VOLUME MAXIMUM: 75 quarts (95 liters)
*
DOMESTIC
GROUND
SHIPPING
INFORMATION
.
CONTACT
FACTORY
FOR
EXPORT
WEIGHT
AND
DIMENSIONS
.
*HALF–SIZE SHEET: 18" x 13" x 1" Ten (10)
*ADDITIONAL WIRE SHELVES REQUIRED FOR
MAXIMUM CAPACITY
*ON WIRE SHELVES ONLY
WATER REQUIREMENTS WATER QUALITY STANDARDS
TWO (2) COLD WATER INLETS - DRINKING QUALITY
ONE (1) TREATED WATER INLET: 3/4" NPT*
ONE (1) UNTREATED WATER INLET: 3/4" NPT*
LINE PRESSURE: 30 to 90 psi 2.1 to 6.3 bar
WATER DRAIN:
1-1/2"
CONNECTION WITH A
2"
MINIMUM AIR GAP INSTALLED AS CLOSE TO THE OVEN AS
POSSIBLE. MATERIALS MUST WITHSTAND TEMPERATURES UP TO
200°F (93°C).
It is the sole responsibility of the owner/operator/purchaser of this equipment
to verify that the incoming water supply is comprehensively tested and if
required, a means of “water treatment” provided that would meet compliance
requirements with the published water quality standards published below.
Non-compliance with these minimum standards will potentially damage this
equipment and/or components and VOID the original equipment manufacturer’s
warranty. Alto-Shaam recommends using OptiPure
®
[www.optipurewater.com]
products to properly treat your water.
CLEARANCE REQUIREMENTS
Contaminant
Free Chlorine
Hardness
Chloride
pH
Silica
Total Dissolved Solids (tds)
Inlet Water Requirements
Less than 0.1 ppm (mg/L)
30-70 ppm
Less than 30 ppm (mg/L)
7.0 to 8.5
Less than 12 ppm (mg/L)
50-125 ppm
LEFT: 0" (0mm) 18" (457mm)
FOR SERVICE ACCESS
RIGHT: 0" (0mm)
NON-COMBUSTIBLE SURFACES
2" (51mm)
COMBUSTIBLE SURFACES
TOP: 20" (508mm)
FOR AIR MOVEMENT
BACK: 4" (102mm) BOTTOM: 5-1/8" (130mm)
FOR LEGS, AIR INTAKE
INSTALLATION REQUIREMENTS
• Oven must be installed level. • Hood installation is required.
• Water supply shut-off valve and back-flow preventer when required by local code.
* Can manifold off of one
3/4" line.
DIMENSIONS: H x W x D
EXTERIOR:
45-11/16" x 35-11/16" x 41-7/16" (1160mm x 906mm x 1053mm)
EXTERIOR WITH RECESSED DOOR:
45-11/16" x 39-11/16" x 41-7/16" (1160mm x 1008mm x 1053mm)
INTERIOR:
31-1/2" x 16-1/4" x 28-1/16" (800mm x 411mm x 712mm)
35-11/16" (906mm)
26-3/16" (665mm)
NOTES:
ALL DIMS DISPLAYED AS H x W x D
INTERIOR DIMENSIONS: 800mm x 411mm x 712mm
•
EXTERIOR DIMENSIONS: 1173mm x 907mm x 995mm
•
6.10 OVER 10.10: 1850mm x 907mm x 995mm
•
10.10 ON 28" STAND: 2013mm x 907mm x 995mm
•
A= UNTREATED WATER
B=TREATED WATER
C= ELECTRICAL
D= WATER DRAIN
10.10es2
805602
45-11/16" (1160mm)
60-9/16" (1538mm)
39-1/4" (996mm)
4-1/2" (114mm)
4-1/4" (108mm)
6-11/16" (168mm)
28-13/16" (731mm)
C - at bottom
of oven
A, B, D
41-7/16" (1053mm)
30-1/2" (775mm)
9-1/16" (230mm)
5-7/8" (149mm)
6-13/16" (171mm)
4-5/16" (109mm)
3-5/16" (84mm)
30-1/2" (775mm)
9-1/16" (230mm)
5-7/8" (149mm)
1-11/16" (42mm)
3-11/16" (93mm)
6-15/16" (176mm)
A
B
C
D
A
B
D
CTC10-10E