Operating instructions
TROUBLESHOOTING
CT EXPRESS STEP BY STEP OPERATION -!.5!,s53
ERROR CODES
Error 
Code
Error Call Out in Display Description of Error Possible Cause
E27
N8 Immersion Element 
Temperature Too High
Immersion element too hot — Scale buildup inside steam generator and/or on water 
level probe.
— Immersion element contactor stuck closed.
— Faulty N8 safety temperature probe.
E34
Steam Generator Drain 
Pump Fault
Water level in steam 
generator does not drop 
during cleaning program
— Scale buildup inside the steam generator and/or
water level probe.
— Obstruction on inlet side of steam generator drain 
pump.
— Boiler steam generator pump not being energized.
— Steam generator drain pump defective.
E36
Steam Temperature High Oven cavity temperature is 
too high when operating in 
steam mode or combination 
mode
— Water supply is not connected or shut off.
— Low water pressure.
— Y1 solenoid valve not energized on a call for steam.
— Y1 solenoid faulty.
— Flow restrictor obstructed.
— Water injection pipe obstructed.
— Steam bypass hose obstructed.
— B5 steam bypass probe dirty or faulty.
E51
No Water In Boiler Steam generator fi ll error — Water supply is disconnected or shut off.
— Low water pressure.
— Boiler drain cap leaking or missing.
— Boiler drain pump defective.
— Drain pump elbow leaking.
— Fill solenoid not energized.
— Fill solenoid faulty.
— Connection/wiring error at the solenoid or the 
relay board.
— Water level probe connection/wiring error at probe 
or the relay board.
— Water level probe requires descaling and/or 
replacement.
E53
Fan Motor High
Temperature
Fan motor high limit — Faulty motor high limit connection at relay board.
— Obstructed fan wheel.
— Faulty convection motor.
E54
Lower Fan Motor High
4EMPERATUREsUNIT
size only)
Fan motor high limit — Faulty motor high limit connection at relay board.
— Obstructed fan wheel.
— Faulty convection motor.
E55
Vent Not Open Browning valve does not open — 
Browning valve vent motor not being energized.
— Alignment issue between motor cam and vent 
motor safety switch (micro switch).
— Faulty connection at vent motor, vent motor switch 
or relay board.
— Fault vent valve safety switch (micro switch).
— Faulty vent motor.
(CONTINUED ON NEXT PAGE)