Operating instructions
CLEANING & MAINTENANCE
CT EXPRESS STEP BY STEP OPERATION -!.5!,s45
VENTLESS HOOD MODEL
TOP EXHAUST VENT
  The charcoal filter should be 
inspected for contaminant's on a regular basis.  
Replacement must be made at a minimum of 
three month intervals — more often if heavy 
contaminant's are visible or if the filter no 
longer controls odors.
   To remove the charcoal filter, pull and slide out. 
When replacing the filter, ensure that the filter 
clip is in place at rear of the filter. Make certain 
the air flow arrow(s) point toward the hood fan 
(back of unit), and that the filter is replaced 
using the filter track in the metal back plate 
provided with the hood.
 
  Cleaning frequency should be 
based on oven usage with a maximum of two 
weeks between cleaning if the oven is used for 
non-grease laden products or steam applications 
only. Grease laden products require cleaning 
frequency of at least once a week.
   Remove the grease filter by pulling it straight 
out of the housing. Place the filter in the 
dishwasher or wash separately by placing in 
hot, soapy water until all grease and particles 
have been removed. Rinse thoroughly. Allow 
the filter to air dry before reinstalling.
   To replace the grease filter, the metal handles 
on the filter casing should be facing toward the 
front of the unit.
 
FILTER TRACK
FILTER SWITCH