Inc. Convection Oven User Manual
 MN-29758(Rev.4)•TH/III&SK/IIIINSTallaTIoN/opeRaTIoN/SeRvIceMaNual pg.13
ELECTRICAL CONNECTION 
INSTALLATION
The appliance must be installed by a qualified 
service technician. The oven must be properly 
grounded in accordance with the National 
Electrical Code and applicable local codes.
Plug the unit into a properly grounded receptacle 
ONLY, positioning the unit so that the plug is 
easily accessible in case of an emergency. Arcing 
will occur when connecting or disconnecting the 
unit unless all controls are in the “OFF” position.
Proper receptacle or outlet configuration or 
permanent wiring for this unit must be installed 
by a licensed electrician in accordance with 
applicable local electrical codes.
REGARDING INTERNATIONAL STANDARD UNITS: 
If the unit is not equipped with flexible cord and 
plug, an all-pole country approved disconnection 
device which has a contact separation of at least 
3mm in all poles must be incorporated in the fixed 
wiring for disconnection. When using a cord 
without a plug, the green/yellow conductor shall 
be connected to the terminal which is marked with 
the ground symbol. If a plug is used, the socket 
outlet must be easily accessible. If the power cord 
needs replacement, use a similar one obtained 
from the distributor.
 DANGER
ENSURE POWER SOURCE 
MATCHES VOLTAGE IDENTIFIED 
ON APPLIANCE RATING TAG.
DANGER
To avoid electrical shock, this 
appliance MUST be adequately 
grounded in accordance with local 
electrical codes or, in the absence of 
local codes, with the current edition 
of the National Electrical Code ANSI/
NFPA No. 70. In Canada, all electrical 
connections are to be made in 
accordance with CSA C22.1, Canadian 
Electrical Code Part 1 or local codes.
NOTE: Where local codes and CE regulatory 
requirements apply, appliances must be 
connected to an electrical circuit that is 
protected by an external GFCI outlet.
Hard wired models:
Hard wired models must be equipped with a 
country certified external allpole disconnection 
switch with sufficient contact separation.
If a power cord is used for the connection of the 
product an oil resistant cord like H05RN or H07RN 
or equivalent must be used.
DANGER
APPLIANCES WITH NO CORD 
PROVIDED BY FACTORY MUST 
BE EQUIPPED WITH A CORD OF 
SUFFICIENT LENGTH TO PERMIT 
THE APPLIANCE TO BE MOVED 
FOR CLEANING. 
ELECTRICAL CONNECTIONS MUST 
BE MADE BY A QUALIFIED SERVICE 
TECHNICIAN IN ACCORDANCE WITH 
APPLICABLE ELECTRICAL CODES.
 To prevent an electrical 
shock hazard between the appliance and other 
appliances or metal parts in close vicinity, an 
equalization-bonding stud is provided. An 
equalization bonding lead must be connected to 
this stud and the other appliances / metal parts 
to provide sufficient protection against potential 
difference. The terminal is marked 
with the following symbol.