User's Manual
MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual • 6
1. An identification tag is permanently mounted on 
the cabinet.
2. Plug cabinet into a properly grounded receptacle 
ONLY, positioning the unit so the power supply 
cord is easily accessible in case of an emergency.
  Arcing will occur when connecting or 
disconnecting the unit unless all controls are in 
the “OFF” position.
3. If necessary, a proper receptacle or outlet 
configuration as required for this unit, must be 
installed by a licensed electrician in accordance 
with applicable, local electrical codes.  
CAUTION
THIS SECTION IS PROVIDED FOR THE ASSISTANCE 
OF QUALIFIED SERVICE TECHNICIANS ONLY AND 
IS NOT INTENDED FOR USE BY UNTRAINED OR 
UNAUTHORIZED SERVICE PERSONNEL.
 DANGER
DISCONNECT UNIT FROM 
POWER SOURCE BEFORE 
CLEANING OR SERVICING.
DANGER
To avoid electrical shock, this 
appliance MUST be adequately 
grounded in accordance with local 
electrical codes or, in the absence of 
local codes, with the current edition 
of the National Electrical Code ANSI/
NFPA No. 70. In Canada, all electrical 
connections are to be made in 
accordance with CSA C22.1, Canadian 
Electrical Code Part 1 or local codes.
ELECTRICAL
INSTALLATION
Wire diagrams are located inside the bonnet of the unit.
ELECTRICAL
  voltage  phase  cycle/hz  amps kW   
  120  1  60  5.3  0.64  nema 5-15p 
15a, 125V plug
208-240  1  60  2.7  0.64 
nema 6-15p
15a, 250V plug
  230  1  50/60  2.6  0.59
  cee 7/7, 
            220-230V plug
For CE approved units: To prevent an electrical 
shock hazard between the appliance and other 
appliances or metal parts in close vicinity, an 
equalization-bonding stud is provided. An 
equalization bonding lead must be connected to 
this stud and the other appliances / metal parts 
to provide sufficient protection against potential 
difference. The terminal is marked 
with the following symbol.
NOTE: Where local codes and CE regulatory 
requirements apply, appliances must be 
connected to an electrical circuit that is 
protected by an external GFCI outlet.
Hard wired models:
Hard wired models must be equipped with a 
country certified external allpole disconnection 
switch with sufficient contact separation.
If a power cord is used for the connection of the 
product an oil resistant cord like H05RN or H07RN 
or equivalent must be used.