Specifications


SERVICE
CALIBRATION PROCEDURES
Every unit is calibrated at the factory. Only a qualified
service technician should calibrate the unit in the field
if necessary.
SHOCK RISK WARNING: Unit must be disconnected
from power source before making adjustments or
calibrating switch.
TOOLS REQUIRED: 2mm allen (hex) wrench
DANGER
DISCONNECT UNIT FROM
POWER SOURCE BEFORE
CLEANING OR SERVICING.
CAUTION
THIS SECTION IS PROVIDED FOR THE ASSISTANCE
OF QUALIFIED SERVICE TECHNICIANS ONLY AND
IS NOT INTENDED FOR USE BY UNTRAINED OR
UNAUTHORIZED SERVICE PERSONNEL.
CABLE HEATING REPLACEMENT SERVICE KITS 100-HW/HWLF 200-HW/HWLF 300-HW/HWLF 400-HW/HWLF 500-HW/HWLF
KIT NUMBER 4877 4878 4880 4881 5 4880
SERVICE KIT INCLUDES:
CB-3045 CABLE HEATING ELEMENT 37 ft 67 ft 132 ft 144 ft 120 ft
CR-3226 RING CONNECTOR 2 4 8 12 8
IN-3488 INSULATION CORNER 8 ft 8 ft 8 ft 8 ft 8 ft
BU-3105 SHOULDER BUSHING 2 4 8 12 8
BU-3106 CUP BUSHING 2 4 8 12 8
SL-3063 INSULATING SLEEVE 2 4 8 12 8
TA-3540 HIGH TEMP ELECTRICAL TAPE 1 roll 1 roll 1 roll 1 roll 1 roll
ST-2439 10.32 STUD 2 4 8 12 8
NU-2215 HEX NUT 4 8 32 24 32