T r o u b l e s h o o T i n g T r e e s • C o m b i t h e r m C t e x p r e s s t e C h n i C a l s e r v i C e m a n u a l • D – 21
troubleshooting trees
No Display/Control not powering on (Unit Dead)
Is voltage across L1/L2 at
main TB?
Is voltage across terminal
1/F1 and terminal 1/F2
6.3A fuses?
Is voltage across terminal 2/F1
and terminal 2/F2 6.3A fuses?
Check cord/plug/main
circuit breaker – Install/
Repair/Reset as needed
No
Yes
Yes
No
Repair wiring between
main TB and F/1F2 fuses
No
Yes
Replace blown F1/F2
fuses(s)
Repair wiring between F1/F2
and Power Supply
Is voltage across L1/N at
power supply?
No
Is 12 VDC across terminals
V+ and V- at power supply?
Replace power supply
Is there 12 VDC across
pin 1-2 on On/Off board?
Test On/Off board cable for
continuity. If cable ok, replace
display board
Is 12 VDC across display
(LCD) terminals DB3 and
DB1?
Repair wiring between power
supply and LCD
Test On/Off board -
On = Temporary switch between 1-3
Off = temporary switch between 1-4
No
Yes
Yes
No
No
Yes
Yes