Service manual
troubleshooting trees
T r o u b l e s h o o T i n g T r e e s • C o m b i t h e r m C t e x p r e s s t e C h n i C a l s e r v i C e m a n u a l • D – 4
No Convection Heat (380-415V, 3PH)
Is N-6 oven temperature
probe below set point?
Is K-41 contactor coil
energized?
Is K-41 contactor closing?
N-6 must be below set
point
No
Yes
Yes
No
L1/A1 from RBH X4/412,
L2/A2 from N7 high limit
No
Yes
Replace K-41 contactor
L1/L2/L3 supplied from K-77
contactor 1/3/5
Is L1/L2/L3 voltage across
terminals 1/3/5 on K-41
contactor?
No
Is voltage across terminals
2/4/6 on K-41 contactor?
Replace K-41 contactor
Is voltage across 3-4
and 2-5 and 1-6 on E-41
convection elements?
Repair wiring between
F10/11/12 fuses and E-41
Is there L1/L2/L3 voltage
across terminal 1 at
F10/11/12 fuses?
Repair blown F10/11/12
fuse(s)
Is E-41 drawing current on
all legs?
No
Yes
Yes
No
No
Yes
Yes
Ohm out E-41 element
and replace if necessary
Convection cycle is
operating
No
Yes
Yes
No
Repair wiring between K-42
and F10/11/12
Is there L1/L2/L3 voltage
across terminal 2 at
F10/11/12 fuses?