User's Manual

Table Of Contents
Installation prerequisites
4-4 iRM4451nn00-2 iRRH Product Description and Installation Guide
Table 4-2 iRM4451nn00-2 iRRH Installer-supplied parts list
4.3 Site preparation
It is a critical that the conditions in this section must be fulfilled before starting work
at the site.
4.4 Site pre-installation visit checklist
To verify site conditions required for the installation of the iRRH are known, a pre-
installation visit, attended by the Operator's representative, the Installer, Altiostar
Networks, and other required parties, must be performed. Tasks required to be
accomplished should include, at a minimum, those listed in Table 4-3.
Qty Part number Part description
Installer-acquired parts for pre-installation requirements
1
As specified per site
requirement
Any splitter/combiner/amp/cable required for
shared
remote antenna.
1
As specified per site
requirement
Power cable, 8 AWG min., shielded, round cable.
Refer to
Power connector on page 3-6 (Installer orders to
length according to site requirement.)
1
L-Com (part no.
FODLCMIL-nn, or
equivalent)
GigE duplex multi-/single-mode fiber-optic cable,
OM1
62.5/125, military fiber cable, with dual LC/dual LC
terminations, nn = length in meters. For additional
information. Refer to Fronthaul connectors on
page 3-8.
1
As specified per site
requirement
AISG RET control cable with 8-pin DIN connector in
required length. Refer to RET connector on
page 3-8.
1 to 2
As specified per site
requirement
4-pr, shielded, outdoor-rated, round alarm cable.
For
additional information, Refer to Alarms connector
on page 3-10.
3
(minimum)
McMaster 3040T13T
(or equiv)
Eyebolt, M8x1.25, 16 mm, SS (third eyebolt to be
used for control line [guide] attachment).