User's Manual
Table Of Contents
- Altiostar Networks iRM4451nn00-2 intelligent Remote Radio Head
- Preface
- Contents
- List of tables
- List of figures
- 1 Introduction
- 2 Safety requirements
- 3 Physical description
- 4 Installation prerequisites
- 5 Installation overview
- 6 Installing the iRM4451nn00-2
- 6.1 Assembling cables
- 6.2 Routing pre-assembled power/GigE optical fronthaul/grounding cables
- 6.3 Installing the mounting bracket
- 6.4 Hoisting the iRM4451nn00-2 on elevated structures
- 6.5 Installing the iRM4451nn00-2 on the mounting bracket
- 6.6 Connecting the grounding cable
- 6.7 Connecting the RET cables
- 6.8 Connecting the GigE optical fronthaul cables
- 6.9 Connecting the RF cables
- 6.10 Connecting the alarms cable
- 6.11 Connecting the –48 V dc power cable
- 6.12 Weatherproofing cable connections
- 6.13 Checking power
- 7 Terms, Acronyms and Abbreviations
Installation prerequisites
4-4 iRM4451nn00-2 iRRH Product Description and Installation Guide
Table 4-2 iRM4451nn00-2 iRRH Installer-supplied parts list
4.3 Site preparation
It is a critical that the conditions in this section must be fulfilled before starting work
at the site.
4.4 Site pre-installation visit checklist
To verify site conditions required for the installation of the iRRH are known, a pre-
installation visit, attended by the Operator's representative, the Installer, Altiostar
Networks, and other required parties, must be performed. Tasks required to be
accomplished should include, at a minimum, those listed in Table 4-3.
Qty Part number Part description
Installer-acquired parts for pre-installation requirements
1
As specified per site
requirement
Any splitter/combiner/amp/cable required for
shared
remote antenna.
1
As specified per site
requirement
Power cable, 8 AWG min., shielded, round cable.
Refer to
Power connector on page 3-6 (Installer orders to
length according to site requirement.)
1
L-Com (part no.
FODLCMIL-nn, or
equivalent)
GigE duplex multi-/single-mode fiber-optic cable,
OM1
62.5/125, military fiber cable, with dual LC/dual LC
terminations, nn = length in meters. For additional
information. Refer to Fronthaul connectors on
page 3-8.
1
As specified per site
requirement
AISG RET control cable with 8-pin DIN connector in
required length. Refer to RET connector on
page 3-8.
1 to 2
As specified per site
requirement
4-pr, shielded, outdoor-rated, round alarm cable.
For
additional information, Refer to Alarms connector
on page 3-10.
3
(minimum)
McMaster 3040T13T
(or equiv)
Eyebolt, M8x1.25, 16 mm, SS (third eyebolt to be
used for control line [guide] attachment).