User's Manual

Table Of Contents
Physical description
iRM4451nn00-2 iRRH Product Description and Installation Guide 3-13
3.2.9 Vent port
A gas permeable vent has been installed on the iRM4451nn00-2 iRRH to help
equalize air pressure inside the enclosure and prevent contaminants such as
water, salt and dust from getting inside (see
Figure 3-12). The vent fitting has a
gas-permeable membrane integrated into a screw-in fitting. It meets the IEC
60529 standard for enclosure ingress protection against particulates and liquids.
The vent should function maintenance-free over the lifetime of the
iRM4451nn00-2.
Fast blink
Varying blink rate, noticeably faster than a slow blink rate (used only as a
location aid/unit ID)
Table 3-5 LED blink rates
Indicator state Description
Table 3-6 LED indicators boot-up sequence
Time (mm:ss)
Indicator name
POWER STATUS FH1 FH2
—OFF OFF OFF
OFF
00:01 Fast blink OFF OFF OFF
00:02 Steady ON Green OFF OFF OFF
00:03 Steady ON Red OFF OFF OFF
00:04 OFF OFF OFF OFF
00:10 Fast blink OFF OFF OFF
00:11 Steady ON green OFF OFF
OFF
00:16 * OFF Slow/Fast flash green
OFF
00:60 * Slow flash green Slow/Fast flash green
OFF
02:30 Steady ON green Steady ON green Slow/Fast flash green
OFF
NOTE: Assumes FH1 is connected and FH2 is not connected. Initial state (—) is power OFF. * means
state remains as previously indicated. GPS lock is achieved at 02:30 as indicated by STATUS LED being
Steady On green.