iRM4451nn00-2 iRRH Product Description and Installation Guide 3-7
cable onto the plug. Assembly instructions (MA_99A5) are found in the kit with the
mating plug.
Figure 3-7 Rosenberger –48 V DC power plug (exploded view)
The power source end of the plug has screw terminals for connection to Installer-
provided 8 AWG power cables. Power cable connection at the source end of the
power cable is shown in
Figure 3-8.
Figure 3-8 Cable connection for supplied 2-pin Rosenberger plug
The mating plug is fastened by turning the coupling nut clockwise 1/4 turn by
hand until it 'clicks' into the locked position. To remove the power plug, twist the
coupling nut counter-clockwise 1/4 turn.
The Installer must assemble the cable on site in a length ordered according to the
site requirement. Use cable type SOOW, 8 AWG (min.), 2-conductor (8/2),
shielded, stranded copper wires, indoor/outdoor, round cable, cable
OD 0.28–0.67 in (7–17 m), rated at 600 V, or equivalent. Cable can be a
maximum of 328 ft (100 m) in length. The Installer is responsible for determining
the power interface requirements at the supply-side of the cable and orders and
installs the required connector, if any.