To connect grounding cable:
1. Fasten the dual-hole grounding lug and cab
le assembly to the iRU4438 iRRH
chassis grounding posts using the two (2) M5-0.8 bolts and washers supplied. See
Figure 5-13.
Figure 5-13 Connecting the grounding cable
2. Tighten the bolts to 2.4 ft-lb (3.2 Nm) using a torque screwdriver.
5.9 Connecting the fronthaul Ethernet cables
This section provides the procedure for connecting the fronthaul CAT-5 Ethernet cable
to the FRONTHAUL 1 or FRONTHAUL 2 Ethernet RJ45 connector sockets located
inside the front access panel. See Figure 5-14.