User`s guide

MULTI-TASKER
11
[OFFmGkUiS]: for a group of cards
This command disables output "m" for each
card in group "k" of unit "i".
m = card output (m = # from 1-6)
Gk = group number (k = # from 1-9)
Ui = unit number (i = # from 0-9)
S = saves command to memory
Example:
1. [OFF1G5U1]: Turns OFF output 1 for each
card in group 5 of unit 1.
2. [OFFG5U1]: Turns OFF all outputs for each
card in group 5 of unit 1.
[OFF…..P]: sets path
This command will set the path for the output,
but it is not active until the switch command is
executed ( [SW] ). Commands ending in "P" are
not executed immediately. The path for outputs
on multiple cards or the same card can be
loaded.
Command Format: [OFFmCnUiP]
m = number (m =1 to 6)
Cn = card ID No. (n = a slot # from 1 to 19)
(1-8 for MT100-101 or 1-4 for MT100-106)
Ui = unit number (i = # from 0-9)
P = path
Example:
If 2 cards are in slot 6 and 7 of unit 3, to enable
outputs 1 and 2 of card 6 and outputs 3 and 4
of card 7, simultaneously use the following
commands:
[OFF12C6U3P]
[OFF34C7U3P]
[SW]
If "F" is included use the [OFFmCnUiPF]
command or the [OFFmCnUiFP] command.
[OFF…..F]: feedback
After processing a command, an OK or ER will
be returned as feedback if "F" is included at the
end of a command string or if the unit ID is
zero.
Example:
[OFF1C2U3F]: if path is not set
[OFF1C2U3PF]: if path is set
7. […S] – Save
This command will save the configuration
command being sent in memory. When
sending the command [ON1C4S], after reset or
power up, output 1 on C4 will be enabled.
8. […P] – Path
This command will set the path for the output,
but it is not active until the switch command,
[SW], is executed. Commands ending in "P" are
not executed immediately. The path for outputs
on multiple cards or the same card can be
loaded. See examples in ON and OFF
commands.
9. […F] – Feedback
After processing a command, an OK or ER will
be returned as feedback if "F" is included at the
end of a command string or if the unit ID is
zero.
10. [SW] – Switch
The switch command immediately connects
inputs and outputs, which were previously set
with the path command on this card and all
other cards in the MT100-100.
The system will return feedback as OK.
11. [WR]
This command groups multiple cards in the
MT100-100 Enclosure. Each unit contains a
maximum of nine groups.
Command Format: [WRCn…GkUi]
Cn = card ID No. (n = slot # from 1 to 19)
(1-8 for MT100-101 or 1-4 for MT100-106)
Gk = group number (k = # from 1-9)
Ui = unit number (i = # from 0-9)