User`s guide

MULTI-TASKER
10
Example:
1) [ON12C5U3]: Turns ON only outputs 1 and
2 of the MT103-104 card located in slot #5
of the MT100-100 Enclosure with unit ID3.
2) [ON3C5U3]: Turns ON only output 3 of the
MT103-104 card located in slot #5 of the
MT100-100 Enclosure with unit ID3. After
the [ON12C5U3] and [ON3C5U3] commands
have been executed, outputs 1, 2 and 3 will
be ON.
3) [ONC5U3]: Turns ON all outputs of the card.
[ONmGkUiS]: for a group of cards
This command enables output "m" for each
card in group "k" of unit "i".
m = card output (m = # from 1-6)
Gk = group number (k = # from 1-9)
Ui = unit number (i = # from 0-9)
S = saves command to memory
Example:
1. [ON1G5U1]: Turns ON output 1 for each
card in group 5 of unit 1.
2. [ONG5U1]: Turns ON all outputs for each
card in group 5 of unit 1.
[ON…..P]: sets path
This command will set the path for the output,
but it is not active until the switch command is
executed ( [SW] ). Commands ending in "P" are
not executed immediately. The path for outputs
on multiple cards or the same card can be
loaded.
Command Format: [ONmCnUiP]
m = output number (m =1 to 6)
Cn = card ID No. (n = a slot # from 1 to 19)
(1-8 for MT100-101 or 1-4 for MT100-106)
Ui= Unit ID number (i = 0 to 9)
P = path
Example:
If 2 cards are in slot 6 and 7 of unit 3:
To enable output 1 of card 6 and output 3 of
card 7 simultaneously, use the following
commands:
[ON1C6U3P]
[ON3C7U3P]
[SW]
If "F" is included use the [ONmCnUiPF]
command or the [ONmCnUiFP] command.
[ON…..F]: feedback
After processing a command, an OK or ER will
be returned as feedback if "F" is included at the
end of a command string or if the unit ID is
zero.
Example:
[ON1C2U3F]: if path is not set
[ON1C2U3PF]: if path is set
6. [OFF]
This command disables one or more outputs of
a single card or a group of cards.
[OFFmCnUiS]: for a single card
This command disables output “m” without
affecting any other outputs.
m = output number (m = 1 to 6)
Cn = card ID No. (n = slot # from 1 to 19)
(1-8 for MT100-101 or 1-4 for MT100-106)
Ui = Unit ID number (i = 0 to 9)
S = saves command to memory
[OFFCnUi]: Turns OFF all outputs of the card
Example:
1) If card 5 of unit 3 has output 1, 2 and 3 ON:
a) [OFF1C5U3]: Turns OFF output 1 while
output 2 and 3 remain ON.
b) [OFF23C5]: Turns OFF output 2 and 3.
c) [OFFC5U3]: Turns OFF all outputs, which is
equivalent to [OFF123456C5U3].