User`s guide

MULTI-TASKER
9
without Ui (use command [SETU0]; see user’s
guide for the MT100-100).
Example:
[VERC3]: for unit ID zero
[VERC3Ui]: for unit ID other than zero
[VERC3]: equivalent to [VERC3U0]
1. [VER]
This command displays the software version
and card type for the MT103-104 card.
Command Format: [VERCnUi]
Cn = card ID No. (n = slot # from 1 to 19)
(1-8 for MT100-101 or 1-4 for MT100-106)
Ui = Unit ID (i = # from 0 to 9) (refer to the
MT100-100 user’s guide for explanation)
Example:
If one MT103-104 card is in slot #2 of unit 3:
To send command [VERC2U3], the Multi-
Tasker™ Enclosure will return:
MT103-104 690-0125-009
690-0125-009 = software version
MT103-104 = card number
2. [C]
This command receives the status of the card.
Command Format: [CnUi]
Cn = card id (n = slot # from 1 to 19)
(1-8 for MT100-101 or 1-4 for MT100-106)
Ui = unit id (i = from 0 to 9) (refer to the
MT100-100 user’s guide for explanation)
Example:
If one MT103-103 card is in slot #2 of unit 3
with output 1 and 2 ON, to send command
[C2U3], the Multi-Tasker™ Enclosure will return
feedback as:
ON:1,2 C02
ON:1,2 = outputs 1 and 2 enabled
C02 = card 2
If there is no card in slot #2 of unit 3, there will
be no feedback.
3. [CiS]
This command saves the current status of the
card's input to output configuration. This
configuration will be restored after system is
reset or powered off then on.
Ci = card number
S = save configuration
If Inputs 1,2,3,4,5 and 6 are enabled, the
feedback after sending the command [C4S], for
slot 4, would be:
ON:1,2,3,4,5,6 C04 Saved
4. [SIGCi]
The Signal Present command tests for the
presence of an input signal on the input. After
sending the command, the feedback will be
either "1" signifying a signal is present, or "0"
indicating no signal was detected.
i = Slot Number
Example:
To check for the presence of an input signal on
card 4, send the command [SIGC4] and verify
feedback of "1" or "0".
5. [ON]
This command enables one or more outputs of
a single card or group of cards.
[ONmCnUiS]: for a single card
This command enables output “m” without
affecting any other outputs.
Default when plugged in = ALL OFF
m = Output number (m = 1 to 6)
Cn = Card ID number (n = 1 to 19)
(1-8 for MT100-101 or 1-4 for MT100-106)
Ui = Unit ID number (i = 0 to 9)
S = saves command to memory