User`s guide
MULTI-TASKER™
400-0394-004
13
25. [?Cn]
This command will return general information
about the card and its status.
Command Format: [?CnUi]
Cn = Card ID (n = # from 1 to max slots)
Ui = Unit ID (i = from 0 to 9)
Example:
There is an MT106-103 in slot 4. Send the
command [?C4] to receive the feedback status.
Each status field begins with a '+' and ends with
the card slot number (ex: C04). The feedback
will be similar to the following:
+MT106-103C05+VR690-0187-003C05
+IN00C05+RS03C05+BR30C05+CN35C05
+CL40C05+SH29C05+HU32C05+CF1C05
+NR0C05+AR0C05+FZ0C05
MT106-103 = Card Type
VR690-0187-004 = Firmware version
IN00 = Input 0 (S-Video)
RS03 = Resolution 03 (1024x768)
BR30 = Brightness 30 (30 out of 48)
CN35 = Contrast 35 (35 out of 48)
CL40 = Color 40 (40 out of 48)
SH29 = Sharpness 29 (29 out of 48)
HU32 = Hue 32 (32 out of 48)
CF1 = Comb Filter On (1=on, 0=off)
NR0 = Noise Reduction Off
(1=on, 0=off)
AR0 = Aspect Ratio 0 (wide)
(0=wide 16:9, 1=standard 4:3)
FZ0 = Freeze (0=off, 1= on)
26. [STA]
This command enables/disables automatic
feedback from the front panel. The command
affects any card with auto-feedback capability,
not just the MT106-103. See the [?Cn]
command for additional details.
Command Format [STA1] = ON
Command Format [STA0] = OFF
NOTE: The INnR and CLR commands will
return feedback on each parameter as
the INnR saved values or CLR default
values are recalled.
Feedback Prefix Definitions:
+IN = Input
+RS = Resolution
+BR = Brightness
+CN = Contrast
+CL = Color
+SH = Sharpness
+HU = Hue
+CF = Comb Filter
+NR = Noise Reduction
+AR = Aspect Ratio
+FZ = Freeze
Example 1:
Command = [MODER5C04]
Feedback = [+RS05C04]
+RS = Resolution
05 = Setting (00-07)
C04 = Card/Slot number
Example 2:
Command = [MODEA1C04]
Feedback = [+AR0C04]
+AR = Aspect Ratio
0 = Wide 16:9 (1 = 4:3)
C04 = Card/Slot number
GROUP COMMANDS
The next few commands are group commands.
These commands do specifically apply to the
MT106-103, but are provided for information only.
27. [WR]
This command groups multiple cards in the
enclosure allowing all the group members to be
controlled simultaneously with the same
command. Each unit may define a maximum of
eight groups.