User`s guide

MULTI-TASKER
8
8
m -from 0 to 128.
6.[OSOnCi]
This command is set Output offset
n - from 0 to 128
7. [ON]
This command enables one or more outputs of a
single card or group of cards.
[ONmCnUi]: for a single card
This command enables output “m” without
affecting any other outputs.
Default when plugged in = ALL OFF
m = Output number (m = 1 to 8)
n = Card ID number (n = 1 to 19)
i = Unit ID number (i = 0 to 9)
Example:
1)
[ON12C5U3]: Turns ON only output 1 and
2 of the MT110-101/103 card located in
slot #5 of the MT100-100 Enclosure with
unit ID3.
2)
[ON3C5U3]: Turns ON only output 3 of the
MT110-101/103 card located in slot #5 of
the MT100-100 Enclosure with unit ID3.
After the [ON12C5U3] and [ON3C5U3]
commands have been executed, output 1,
2 and 3 will be ON.
3)
[ONC5U3]: Turns ON all outputs of the
card.
[ONmGkUi]: for a group of cards
This command enables output "m" for each
card in group "k" of unit "i".
m = card output (m = # from 1-8)
k = group number (k = # from 1-9)
i = unit number (i = # from 0-9)
Example:
1. [ON1G5U1]: Turns ON output 1 for each
card in group 5 of unit 1.
2. [ONG5U1]: Turns ON all outputs for each
card in group 5 of unit 1.
[ON….. P]: sets path
This command will set the path for the output,
but it is not active until the switch command is
executed ( [SW] ). Commands ending in "P"
are not executed immediately. The path for
outputs on multiple cards or the same card
can be loaded.
Command Format: [ONmCnUiP]
m = output number (m =1 to 8)
n = card ID No. (n = a slot # from 1 to 19)
P = path
Example:
If 2 cards are at slot 6 and 7 of unit 3:
To enable output 1 and 2 of card 6 and output
3 and 4 of card 7 simultaneously, use the
following commands:
[ON12C6U3P]
[ON34C7U3P]
[SW]
If "F" is included use the [ONmCnUiPF]
command or the [ONmCnUiFP]
command.
[ON…..F]: feedback
After processing a command, an OK or ER will
be returned as feedback if "F" is included at
the end of a command string or if the unit ID is
zero.
Example:
[ON1C2U3F]: if path is not set
[ON1C2U3PF]: if path is set
8. [OFF]
This command disables one or more outputs of a
single card or a group of cards.
[OFFmCnUi]: for a single card
This command disables output “m” without
affecting any other outputs.
m = output number (m = 1 to 8)
n = card ID No. (n = slot # from 1 to 19)
i= Unit ID number (i = 0 to 9)
[OFFCnUi]: Turns OFF all outputs of the card
Example:
1) If card 5 of unit 3 has output 1, 2 and 3
ON:
a)
[OFF1C5U3]: Turns OFF output 1 while