Specifications
MULTITASKER
™
12
12
To enable output 1 and 2 of card #6 and
output 3 and 4 of card #17 simultaneously, use
the following commands:
[OFF12C6U3P]
[OFF34C17U3P]
[SW]
If "F" is included use the [OFFmCnUiPF]
command or the [OFFmCnUiFP]
command.
7.3.16. [SW]
The switch command immediately connects
inputs and outputs, which were previously set
with the path command on this card or any
other cards in the MultiTasker™.
Example:
[ON12C6U3P]
[ON34C7U3P]
[SW]
The system will return feedback as OK if the
unit ID is zero.
7.4. SUMMARY OF COMMANDS
[HELPCi]: Displays all RS-232 commands.
[Ci]: Displays the card’s Input/Output status.
[VERCi]: Displays the card’s firmware version.
[IO]: Connects the input to the output
[ON]: Turns on one or more outputs for a
single card or a group of cards.
[OFF]: Turns off one or more outputs for a
single card or a group of cards.
[OSI]: Set the Input offset.
[OSO]: Set the Output offset.
[SEL]: Select inputs to adjust gain with +/-
commands.
[VOL]: Set absolute gain level on the input
[MAT]: Set matrix size.
[CLR]: Reset to Factory defaults.
[…S]: Save Output default status.
[…F]: Enable feedback.
[…P]: Set path for Input to Output connection.
[SW]: Switch (outputs the preloaded buffer)
TROUBLESHOOTING GUIDE 8
We have carefully tested and have found no
problems in the supplied MT110-104. However, we
would like to offer suggestions for the following:
8.1. NO SOUND
A) Cause 1: The source has a problem.
Solution: Check the source and make sure
that it is working at an
appropriate volume level and all
source connections are correct. If
the source is working and there
is still no sound, see Cause 2.
B) Cause 2: The proper input card may not
be selected.
Solution: Select the card input that is
used, by RS-232 accessible
commands in section 7. If no
sound is present, see Cause 3.
C) Cause 3: Cable connections to the
destination are incorrect.
Solution: Make sure that cables are
connected properly. Also, make
sure that the continuity and
wiring are good. If there is still no
sound present, see Cause 4.
D) Cause 4: The destination amplifier has a
problem.
Solution 1: Make sure that the destination
amplifier is powered. If there is
still no sound, see Solution 2
Solution 2: Set the volume of the destination
amplifier to a reasonable level. If
there is still no sound, call
ALTINEX at (714) 990-2300. or
1-800-ALTINEX.