Specifications
MULTITASKER
ā¢
11
11
The 16x16 configuration will switch each
individual input to each individual output,
e.g. : [I2O1C5] will connect input2 with
output1.
The 8x8 configuration will switch 2 inputs to 2
outputs at the same time,
e.g. : [I2O1C5] will connect input2a with
output1a and input2b with output1b,
etc.
The 4x4 configuration will switch 4 inputs to 4
outputs at the same time.
e.g. : [I3O2C5] will connect input3a to
output2a, 3b to 2b, 3c to 2c, and 3d
to 2d.
The 2x2 configuration will switch 8 inputs to 8
outputs at the same time.
e.g. : [I1O2C5] will connect input1a to
output2a, 1b to 2b, 1c to 2c, and 1d
to 2d, 1e to 2e, 1f to 2f, 1g to 2g,
and 1h to 2h.
7.3.12. [CLR]
This command resets the card selected to the
factory default configuration (Input 1 to all
Outputs, all Outputs ON).
Command Format: [CLRCi]
Ci = card ID number (i = number from 4 to 19)
7.3.13. [....S]: Save Output Default Status
Include the āSā option at the end of the
command string to save the output default
status.
Examples:
[ON1C8U3S]
[OFF12C6U3S]
7.3.14. [....F]: Feedback
After processing a command, an OK or ER will
be returned as feedback if "F" is included at
the end of a command string or if the unit ID is
zero.
Example:
[ON1C8U3F]: if path is not set
[ON1C8U3PF]: if path is set
7.3.15. [ā¦.P]: Path
Commands ending in "P" are not executed
immediately. This command will set the path
for the input to output connection, but it is not
active until the switch command [SW]. is
executed The path for outputs on multiple
cards or the same card can be loaded.
Command Format example: [OFFmCnUiP]
m = number (m =1 to 16)
n = card ID No. (n = a slot # from 1 to 19)
P = path
Example:
If 2 cards are at slot #6 and #17 of unit #3:
2x2
Input Output
O2a O1a O1a O2a
O2b O1b O1b O2b
O2c O1c O1c O2c
O2d O1d O1d O2d
O2e O1e O1e O2e
O2f O1f O1f O2f
O2g O1g O1g O2g
O2h O1h O1h O2h
4x4
Input Output
O3a O1a O1a O3a
O3b O1b O1b O3b
O3c O1c O1c O3c
O3d O1d O1d O3d
O4a O2a O2a O4a
O4b O2b O2b O4b
O4c O2c O2c O4c
O4d O2d O2d O4d