Specifications
MULTITASKER
ā¢
9
9
Example:
If one MT110-104 card is in slot #8 with
outputs 1, 2 & 3 ON:
When sending command [C8]
, feedback will
be returned as:
OFFSET: INPUT=0 OUTPUT=0
In01 Out1 VOLn = ON/OFF
In03 Out2 VOLn = ON/OFF
In06 Out3 VOLn = ON/OFF
In02 Out4 VOLn = ON/OFF
In09 Out5 VOLn = ON/OFF
In16 Out6 VOLn = ON/OFF
In13 Out7 VOLn = ON/OFF
In10 Out8 VOLn = ON/OFF
Note that for volume setting VOLn, ānā will be a
value from 0 to 16 (see [VOL] command).
If there is no card in slot #8, sending the
[C8U3] command will not return any feedback.
7.3.3. [VER]
This command receives the firmware version
and card type for the MT110-104 card.
Command Format: [VERCi]
Ci = card ID number (i = number from 4 to 19)
Example:
If one MT110-104 card is in slot #8 of unit #3:
Send command [VERC8U3
]; the
MultiTasker⢠enclosure will return:
MT110-104 690-0167-001
(The last 3 numbers of the firmware number
will indicate version 001 or higher)
7.3.4. [IO]
This command will connect input x with output
y, but the user needs to use the [ON]
command to enable this output.
Command Format: [ImOnCi]
Im = select Input m (m = 1 to 16)
On = connect to output n (n = from 1 to 16)
Ci = card ID (i = a slot number from 4 to 19)
Example:
To connect input 4 to output 2 on the card in
slot #8, use the [I4O2C8] command.
To connect input 4 to all of the outputs on the
card in slot #8, use [I4O*C8]
7.3.5. [ON]
This command enables the selected output
without affecting any other outputs.
Default when plugged in = ALL OFF
Command Format: [ONnCi]
n = Output number from 1 to 16
Ci = card ID (i = a slot number from 4 to 19)
Examples:
[ON12C5]
: Turns ON only output #12 of the
card located in slot #5.
[ON3C5]: Turns ON only output #3 of the card
located in slot #5. After the [ON12C5] and
[ON3C5] commands have been executed,
outputs #1, #2 and #3 will be ON.
[ONC5]: Turns ON all outputs of the card in
slot #5.
7.3.6 [OFF]
This command disables the selected output
without affecting any other outputs.
Command Format: [OFFnCi]
n = Output number from 1 to 16
Ci = card ID (i = a slot number from 4 to 19)
Examples:
[OFF12C5]: Turns OFF only output #12 for the
card located in slot #5.
[OFFC5]: Turns OFF all outputs of the card
located in slot #5.
7.3.7. [OSI]
This command sets the input offset value.