User`s guide

MULTI-TASKER™
400-0202-002 19
7.4.5 MENU MODE EXAMPLES
All MENU MODE examples assume an
MT104-106 is installed in slot #4. Start by
clicking the mouse in the Terminal window.
Press ENTER and a list of available cards will
be displayed.
1. Select An Input
Follow the keystrokes below to select Input 3 as
the source input.
Enter List available cards
04 Select MT104-106 in slot #4
1 Select CONTROL Menu
4 Select SWITCH Control
3 Select Input 3
S Show input selection again, this time
INPUT3 is at the top of the SWITCH
menu.
ESC Return to CONTROL Menu
ESC Return to the MAIN Menu
2. Assign card to Group 1
Starting from the main menu, make the card in
slot #4 part of Group 1. Follow the keystrokes
below.
2 Select SETUP Menu
1 Select Set Group ID
1 Select Assign Group ID
1 Assign to Group 1
ESC Return to Set Group Menu
ESC Return to SETUP Menu
ESC Return to the MAIN Menu
3. Save Card Settings
Starting from the main menu, set the ramp time
to 10 seconds. Follow the keystrokes below.
1 Select CONTROL Menu
2 Select SAVE Control
1 Answer YES to save
ESC Return to the MAIN Menu
4. Display Card Status
Starting from the Main Menu, follow the
keystrokes below.
3 Displays card status
NOTE: The status will be displayed, followed
by the Main Menu being redisplayed.
TROUBLESHOOTING GUIDE 8
We have carefully tested and have found no
problems in the supplied MT104-106. However,
we would like to offer suggestions for the following:
8.1 LED IS NOT LIT
Cause 1: Card cage is not plugged in.
Solution: Plug card cage in. If the LED lights,
the problem is solved. If the LED is
still not ON, see Cause 2.
Cause 2: Card is not plugged in all the way.
Solution: Push the card in all the way. If the
LED is still not ON, see Cause 3.
Cause 3: Card cage slot has a problem.
Solution 1: Test the card in other slots of the
card cage. If the slot was damaged,
the card may work in other slots. If
other slots work and the LED lights,
the problem is the card cage slot.
The card cage may require service.
Call ALTINEX at (714) 990-2300. If
the other slots do not work and the
LED is still not lit, see Solution 2.
Solution 2: Take any other known good card
with an LED and verify that the slot
used is good by seeing if the other
card’s LED lights in that slot. If it
lights, then the original card may be
the source of the problem. Call
ALTINEX at (714) 990-2300.