User`s guide
MULTI-TASKERâ„¢
18
3: STATUS
Equivalent to the [VER] and [C] commands.
Returns the card number, firmware revision
and status.
4: HELP
Equivalent to the [HELP] command.
Displays a list of commands available for
the MT103-127/128 along with a brief
description.
ESC
Returns to the parent menu.
7.4.5 MENU MODE EXAMPLES
All MENU MODE examples assume an
MT103-127/128 is installed in slot #1. Start by
clicking the mouse in the Terminal window.
Press ENTER and a list of available cards will
be displayed.
1. Reset the card to factory default settings
Follow the keystrokes below:
Enter List available cards
1 Select MT103-127/128 in slot #1
1 Select the CONTROL menu
1 Select CLEAR
1 YES to confirm clear
ESC Return to the MAIN Menu
2. Set the Equalization to 25, starting at 20
Starting from the Main Menu, follow the
keystrokes below.
2 Select SETUP menu
1 Select SET EQUALIZATION
1 Increment by 1
Feedback returns EQ=21
1 Increment by 1 (EQ=22)
1 Increment by 1 (EQ=23)
1 Increment by 1 (EQ=24)
1 Increment by 1 (EQ=25)
ESC Return to SETUP menu
ESC Return to the Main Menu
3. Display Card Status
Starting from the Main Menu, follow the
keystrokes below.
3 Displays card status
TROUBLESHOOTING GUIDE 8
We have carefully tested and have found no
problems in the supplied MT103-127/128;
however, we would like to offer suggestions for the
following:
8.1 NO DISPLAY
Cause 1: The source has a problem.
Solution: Check the source and make sure
that there is a signal present and all
source connections are correct. If
the source is working and there is
still no display, see Cause 2.
Cause 2: Cable connections to the
destination are incorrect.
Solution: Make sure that cables are
connected properly. Also, make
sure that the continuity and wiring
are good. If there is still no display
present, see Cause 3.
Cause 3: The display has a problem.
Solution: Make sure that the display is
powered. If there is still no display,
call ALTINEX at (714) 990-2300.